Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / Riello UPS Power Supply / Riello Master HP UL UPS MHT UL 65

Riello Master HP UL UPS MHT UL 65

Riello Master HP UL UPS MHT UL 65
share

Specifications:
INPUT
Voltage 480 Vac tolerance + N Vac
Frequency 45 ÷ 65 Hz
Power factor > 0,99
Current distorsion <3%
Soft start 0 ÷ 100% in 30"
OUTPUT
Rated power 65000 VA
Active power 58500 W

Riello Net Power UPS NPW 2000
Riello Net Power UPS NPW 2000
Specifications: NPUT Rated power 2000 VA Voltage 220-240 Vac Voltage tolerance 230 Vac (+ 20 / - 26%) Frequency 50/60 Hz auto sensing OUTPUT and INVERTER OUTPUT Rated power 2000 VA Active power 1200 W Wave form on battery Pseudo sinewave Frequency on battery operation 50 or 60 Hz (± 0.5%)
Riello Vision Dual UPS VSD 3000
Riello Vision Dual UPS VSD 3000
Specifications: INPUT Rated power 3000 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 3000 VA Active power 2700 W Number phases 1 Crest factor (Ipea
Riello Sentinel Dual (Low Power) UPS SDH 3000 ER
Riello Sentinel Dual (Low Power) UPS SDH 3000 ER
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency
Riello Vision UPS VST 800
Riello Vision UPS VST 800
Specifications:INPUTRated power 800 VAVoltage 230 VacFrequency 50/60 Hz with autorangeFrequency tolerance ± 5%OUTPUT and INVERTER OUTPUTRated power 800 VAActive power 540 WNumber phases 1Waveform SinewaveFrequency 50/60 Hz with autorange
Riello Dialog Vision UPS DVR 1100
Riello Dialog Vision UPS DVR 1100
Specifications: INPUT Rated power 1100 VA Voltage 230 Vac Frequency 50/60 Hz with autorange Frequency tolerance ± 10Hz OUTPUT and INVERTER OUTPUT Rated power 1100 VA Active power 740 W Number phases 1 Waveform Sinewave Frequency 50 or 60 Hz with autorange BATTERIES Type Maintenance-fre
Riello Dialog Vision UPS DVR 500
Riello Dialog Vision UPS DVR 500
Specifications: INPUT Rated power 500 VA Voltage 230 Vac Frequency 50/60 Hz with autorange Frequency tolerance ± 10Hz OUTPUT and INVERTER OUTPUT Rated power 500 VA Active power 335 W Number phases 1 Waveform Sinewave Frequency 50 or 60 Hz with autorange BATTERIES Type Maintenance-free
Riello Master HP UL UPS MHT UL 100
Riello Master HP UL UPS MHT UL 100
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)100/90 %Input voltage distoration (THDi) <3 Outpu
Riello Sentinel Pro UPS SEP 1500
Riello Sentinel Pro UPS SEP 1500
Specifications:INPUTRated power 1500 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Master HP UL UPS MHT UL 250
Riello Master HP UL UPS MHT UL 250
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)250/225 %Input voltage distoration (THDi) <3 Outpu
Riello iDialog UPS IDG 400
Riello iDialog UPS IDG 400
Specifications:INPUTRated power 400 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 400 VAActive power 240 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)BATTERIES