Specifications:
INPUT
Voltage 480 Vac tolerance + N Vac
Frequency 45 ÷ 65 Hz
Power factor > 0,99
Current distorsion <3%
Soft start 0 ÷ 100% in 30"
OUTPUT
Rated power 65000 VA
Active power 58500 W

Riello Sentinel Dual (Low Power) UPS SDH 3000
Riello Sentinel Dual (Low Power) UPS SDH 3000
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency
Riello Sentinel Dual (High Power) UPS SDL 6000
Riello Sentinel Dual (High Power) UPS SDL 6000
Specifications:INPUTRated power 6000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Net Power UPS NPW 1000
Riello Net Power UPS NPW 1000
Specifications: INPUT Rated power 1000 VA Voltage 220-240 Vac Voltage tolerance 230 Vac (+ 20 / - 26%) Frequency 50/60 Hz auto sensing OUTPUT and INVERTER OUTPUT Rated power 1000 VA Active power 600 W Wave form on battery Pseudo sinewave Frequency on battery operation 50 or 60 Hz (± 0.5%)
Riello Vision Dual UPS VSD 1500
Riello Vision Dual UPS VSD 1500
Specifications: INPUT Rated power 1500 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 1500 VA Active power 1350 W Number phases 1 Crest factor (Ipea
Riello Sentinel Pro UPS SEP 3000
Riello Sentinel Pro UPS SEP 3000
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello iDialog UPS IDG 1600
Riello iDialog UPS IDG 1600
Specifications:INPUTRated power 1600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 1600 VAActive power 960 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)
Riello Master FC400 UPS MFC 120
Riello Master FC400 UPS MFC 120
Specifications: SKU MFC120 Power 120kVA/96kW Runtime Add external battery extension Input Connection Hardwired terminals Input Voltage 380/400/415Vac 3phase, 45-65Hz Output Connection Hardwired terminals Output Voltage 208Vac 3phase+N +/-1%, 400Hz +/- 0.05% Dimensions (WxDxH) 550x740x1200mm
Riello Multi Sentry UPS MCM 20
Riello Multi Sentry UPS MCM 20
Specifications:INPUTRated power 20000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Sentinel Power Green UPS SPM 6
Riello Sentinel Power Green UPS SPM 6
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 6000 VAActive power 5400 WWaveform SinusoidalOVERLOAD TIMES
Riello Multi Sentry UPS MST 120
Riello Multi Sentry UPS MST 120
Specifications:INPUTRated power 120000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.2