Riello Master HP UL UPS MHT UL 65

Riello Master HP UL UPS MHT UL 65
share

Specifications:
INPUT
Voltage 480 Vac tolerance + N Vac
Frequency 45 ÷ 65 Hz
Power factor > 0,99
Current distorsion <3%
Soft start 0 ÷ 100% in 30"
OUTPUT
Rated power 65000 VA
Active power 58500 W

Riello Multi Sentry UPS MCT 12
Riello Multi Sentry UPS MCT 12
Specifications:INPUTRated power 12000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Multi Sentry UPS MCM 10
Riello Multi Sentry UPS MCM 10
Specifications:INPUTRated power 10000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Master HE UPS MHE 250
Riello Master HE UPS MHE 250
Specifications: INPUT Rated power 250000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 352 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Multi Sentry UPS MST 100
Riello Multi Sentry UPS MST 100
Specifications:INPUTRated power 100000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.2
Riello Master HP UL UPS MHT UL 160
Riello Master HP UL UPS MHT UL 160
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)160/144 %Input voltage distoration (THDi) <3 Outpu
Riello Master Industrial UPS MIM 40
Riello Master Industrial UPS MIM 40
Specifications: INPUT Rated power 40000 VA Voltage 400 Vac three-phase Vac Voltage tolerance ± 20% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0.93 Current distorsion <5% Soft start 0-100% in 120" configurable BY PASS Rated voltage 400 Vac three-phase s
Riello Master FC400 UPS MFC 80
Riello Master FC400 UPS MFC 80
Specifications: SKU MFC80 Power 80kVA/64kW Runtime Add external battery extension Input Connection Hardwired terminals Input Voltage 380/400/415Vac 3phase, 45-65Hz Output Connection Hardwired terminals Output Voltage 208Vac 3phase+N +/-1%, 400Hz +/- 0.05% Dimensions (WxDxH) 550x740x1200mm N
Riello Master MPS UPS MPT 80
Riello Master MPS UPS MPT 80
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph
Riello Sentinel Dual (Low Power) UPS SDH 2200 ER
Riello Sentinel Dual (Low Power) UPS SDH 2200 ER
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency
Riello Sentinel Dual (Low Power) UPS SDH 3000
Riello Sentinel Dual (Low Power) UPS SDH 3000
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency