Riello Master HP UPS MHT 400

Riello Master HP UPS MHT 400
share

Specifications
INPUT
Rated power 400000 VA
Voltage 400 Vac three-phase Vac
Voltage tolerance + 20% - 25%
Frequency 50/60 Hz with autorange
Frequency tolerance 45/65 Hz
Power factor 0,99
Input current 564 A
Current distorsion <3%
Soft start 0-100% in 10
BY PASS
Rated voltage 400 Vac three-phase selectable 380 and 415
Voltage tolerance ± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency 50/60 Hz (autorange)
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Rated current 564 A
Number phases 3
Back-feed protection yes
Overload capacity Inx10ms 14
OUTPUT and INVERTER OUTPUT
Rated power 400000 VA
Active power 360000 W
Number phases 3 + N
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Dynamic stability ± 5% in 5 ms
Frequency same as the input (autorange)
Voltage distortion with distorcing load <3%
Voltage distortion with linear load <1%
Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5% from front panel) with mains supply present
Inverter efficiency at rated load 95 %
Overload 125% 150% 200% of the rated current for 10' / 1' / 7

Riello Master HP UPS MHT 500
Riello Master HP UPS MHT 500
SpecificationsINPUTRated power 500000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 702 ACurrent distorsion
Riello Master HP UL UPS MHT UL 100
Riello Master HP UL UPS MHT UL 100
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)100/90 %Input voltage distoration (THDi) <3 Outpu
Riello Vision UPS VST 1100
Riello Vision UPS VST 1100
Specifications:INPUTRated power 1100 VAVoltage 230 VacFrequency 50/60 Hz with autorangeFrequency tolerance ± 5%OUTPUT and INVERTER OUTPUTRated power 1100 VAActive power 880 WNumber phases 1Waveform SinewaveFrequency 50/60 Hz with autorangeBATTERIESType Maintenance-free sealed lead acidTypical recha
Riello Master Industrial UPS MIM 30
Riello Master Industrial UPS MIM 30
Specifications: INPUT Rated power 30000 VA Voltage 400 Vac three-phase Vac Voltage tolerance ± 20% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0.93 Input current 145 A Current distorsion <3% in 12MP HC version Soft start 0-100% in 120" configurable BY P
Riello Net Power UPS NPW 2000
Riello Net Power UPS NPW 2000
Specifications: NPUT Rated power 2000 VA Voltage 220-240 Vac Voltage tolerance 230 Vac (+ 20 / - 26%) Frequency 50/60 Hz auto sensing OUTPUT and INVERTER OUTPUT Rated power 2000 VA Active power 1200 W Wave form on battery Pseudo sinewave Frequency on battery operation 50 or 60 Hz (± 0.5%)
Riello Sentinel Power UPS SPW 6000
Riello Sentinel Power UPS SPW 6000
Specifications:INPUTRated power 6000 VAVoltage 220-230-240 VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OU
Riello Master HP UPS MHT 100
Riello Master HP UPS MHT 100
SpecificationsINPUTRated power 100000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 141 ACurrent distorsion
Riello Vision Dual UPS VSD 2200 ER
Riello Vision Dual UPS VSD 2200 ER
Specifications: INPUT Rated power 2200 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 2200 VA Active power 1760 W Number phases 1 Crest factor (Ipea
Riello Sentinel Power UPS SPT 8000
Riello Sentinel Power UPS SPT 8000
Specifications:INPUTRated power 8000 VAVoltage 220-230-240 Vac single-phase or 380-400-415 Vac three-phase with neutral VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequ
Riello Master HP UPS MHT 120
Riello Master HP UPS MHT 120
SpecificationsINPUTRated power 120000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 169 ACurrent distorsion