Specifications:
Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel
Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable
Waveform Sinusoidal
Power(KVA/KW)100/90
%Input voltage distoration (THDi) <3
Output voltage distoration (THDu) <1% with linear load, <3% with distorance load
Noise level @ 1m 65 dBA 68 dBA
Battery voltage 480 VDC
Overload time(to 110% load) For 60 minutes
Overload time(to 125% load) For 10 minutes
Overload time(to 150% load) For 1 minute

Riello Sentinel Dual (High Power) UPS SDL 10000 TM
Riello Sentinel Dual (High Power) UPS SDL 10000 TM
Specifications:INPUTRated power 10000 VAVoltage 380-400-415 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERT
Riello Master HP UL UPS MHT UL 65
Riello Master HP UL UPS MHT UL 65
Specifications: INPUT Voltage 480 Vac tolerance + N Vac Frequency 45 ÷ 65 Hz Power factor > 0,99 Current distorsion <3% Soft start 0 ÷ 100% in 30" OUTPUT Rated power 65000 VA Active power 58500 W
Riello Multi Sentry UPS MCT 12
Riello Multi Sentry UPS MCT 12
Specifications:INPUTRated power 12000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Master Industrial UPS MIM 30
Riello Master Industrial UPS MIM 30
Specifications: INPUT Rated power 30000 VA Voltage 400 Vac three-phase Vac Voltage tolerance ± 20% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0.93 Input current 145 A Current distorsion <3% in 12MP HC version Soft start 0-100% in 120" configurable BY P
Riello Master HE UPS MHE 120
Riello Master HE UPS MHE 120
Specifications: INPUT Rated power 120000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 169 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Master HP UPS MHT 100
Riello Master HP UPS MHT 100
SpecificationsINPUTRated power 100000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 141 ACurrent distorsion
Riello iPlug UPS IPG 600
Riello iPlug UPS IPG 600
Specifications:INPUTRated power 600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz with auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (+/- 1%)
Riello Master HP UPS MHT 120
Riello Master HP UPS MHT 120
SpecificationsINPUTRated power 120000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 169 ACurrent distorsion
Riello Master HE UPS MHE 500
Riello Master HE UPS MHE 500
Specifications: INPUT Rated power 500000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 702 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Master HE UPS MHE 800
Riello Master HE UPS MHE 800
Specifications: INPUT Rated power 800000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 1122 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac