Specifications
INPUT
Rated power 120000 VA
Voltage 400 Vac three-phase Vac
Voltage tolerance + 20% - 25%
Frequency 50/60 Hz with autorange
Frequency tolerance 45/65 Hz
Power factor 0,99
Input current 169 A
Current distorsion <3%
Soft start 0-100% in 10
BY PASS
Rated voltage 400 Vac three-phase selectable 380 and 415
Voltage tolerance ± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency 50/60 Hz (autorange)
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Rated current 169 A
Number phases 3
Back-feed protection yes
Overload capacity Inx10ms 14
OUTPUT and INVERTER OUTPUT
Rated power 120000 VA
Active power 108000 W
Number phases 3 + N
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Dynamic stability ± 5% in 5 ms
Frequency same as the input (autorange)
Voltage distortion with distorcing load <3%
Voltage distortion with linear load <1%
Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5% from front panel) with mains supply present
Overload 125% 150% 200% of the rated current for 10' / 1' / 7

Riello Dialog Vision UPS DVR 800
Riello Dialog Vision UPS DVR 800
Specifications: INPUT Rated power 800 VA Voltage 230 Vac Frequency 50/60 Hz with autorange Frequency tolerance ± 10Hz OUTPUT and INVERTER OUTPUT Rated power 800 VA Active power 540 W Number phases 1 Waveform Sinewave Frequency 50 or 60 Hz with autorange BATTERIES Type Maintenance-free
Riello Master HP UL UPS MHT UL 250
Riello Master HP UL UPS MHT UL 250
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)250/225 %Input voltage distoration (THDi) <3 Outpu
Riello Master HP UL UPS MHT UL 80
Riello Master HP UL UPS MHT UL 80
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)80/72 %Input voltage distoration (THDi) <3 Output
Riello Master HP UPS MHT 160
Riello Master HP UPS MHT 160
SpecificationsINPUTRated power 160000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 226 ACurrent distorsion
Riello Multi Sentry UPS MCM 12
Riello Multi Sentry UPS MCM 12
Specifications:INPUTRated power 12000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello iDialog UPS IDG 1200
Riello iDialog UPS IDG 1200
Specifications:INPUTRated power 1200 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 1200 VAActive power 720 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)
Riello Master Industrial UPS MIM 60
Riello Master Industrial UPS MIM 60
Specifications: INPUT Rated power 60000 VA Voltage 400 Vac three-phase Vac Voltage tolerance ± 20% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0.93 Current distorsion <5% Soft start 0-100% in 10" BY PASS Rated voltage 400 Vac three-phase selectable 380
Rielloi Dialog Rack UPS IDR 600
Rielloi Dialog Rack UPS IDR 600
Specifications:INPUTRated power 600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)BATTERIES
Riello Net Power UPS NPW 2000
Riello Net Power UPS NPW 2000
Specifications: NPUT Rated power 2000 VA Voltage 220-240 Vac Voltage tolerance 230 Vac (+ 20 / - 26%) Frequency 50/60 Hz auto sensing OUTPUT and INVERTER OUTPUT Rated power 2000 VA Active power 1200 W Wave form on battery Pseudo sinewave Frequency on battery operation 50 or 60 Hz (± 0.5%)
Riello Master HP UL UPS MHT UL 100
Riello Master HP UL UPS MHT UL 100
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)100/90 %Input voltage distoration (THDi) <3 Outpu