Specifications:
SKU MFC100
Power 100kVA/80kW
Runtime Add external battery extension
Input Connection Hardwired terminals
Input Voltage 380/400/415Vac 3phase, 45-65Hz
Output Connection Hardwired terminals
Output Voltage 208Vac 3phase+N +/-1%, 400Hz +/- 0.05%
Dimensions (WxDxH) 550x740x1200mm
Nett Weight 330Kg
Delivery Time Typically within 15-20 working days
Maintenance Plan 4 clock hours, 8 and 12 working hours, remote monitoring
Warranty 36 months (extended available)

Riello Master HP UL UPS MHT UL 100
Riello Master HP UL UPS MHT UL 100
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)100/90 %Input voltage distoration (THDi) <3 Outpu
Riello Sentinel Dual (High Power) UPS SDL 5000
Riello Sentinel Dual (High Power) UPS SDL 5000
Specifications:INPUTRated power 5000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Master MPS UPS MPT 200
Riello Master MPS UPS MPT 200
Specifications:NPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated freq
Riello Master MPS UPS MPT 40
Riello Master MPS UPS MPT 40
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph
Riello Multi Sentry UPS MCM 10
Riello Multi Sentry UPS MCM 10
Specifications:INPUTRated power 10000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Sentinel Dual (High Power) UPS SDL 10000
Riello Sentinel Dual (High Power) UPS SDL 10000
Specifications:INPUTRated power 10000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERT
Riello Multi Sentry UPS MST 40
Riello Multi Sentry UPS MST 40
Specifications:INPUTRated power 40000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Master HP UPS MHT 500
Riello Master HP UPS MHT 500
SpecificationsINPUTRated power 500000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 702 ACurrent distorsion
Riello Sentinel Dual (High Power) UPS SDL 6500 TM
Riello Sentinel Dual (High Power) UPS SDL 6500 TM
Specifications:INPUTRated power 6500 VAVoltage 380-400-415 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Master HE UPS MHE 600
Riello Master HE UPS MHE 600
Specifications: INPUT Rated power 600000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 842 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t