Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / Riello UPS Power Supply / Riello Sentinel Dual (High Power) UPS SDL 6000

Riello Sentinel Dual (High Power) UPS SDL 6000

Riello Sentinel Dual (High Power) UPS SDL 6000
share

Specifications:
INPUT
Rated power 6000 VA
Voltage 220-230-240 Vac
Frequency 50/60 Hz ± 5 Hz
Power factor >0.98
Current distorsion ≤5%
BY PASS
Voltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)
Frequency tolerance Selected frequency ± 5% (user configurable)
OUTPUT and INVERTER OUTPUT
Rated power 6000 VA
Active power 4200 W
Number phases 1
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Frequency 50/60 Hz selectable
Voltage distortion with distorcing load <5%
Voltage distortion with linear load <3%

Riello Master Industrial UPS MIM 80
Riello Master Industrial UPS MIM 80
Specifications: INPUT Rated power 80000 VA Voltage 400 Vac three-phase Vac Voltage tolerance ± 20% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0.93 Current distorsion <5% Soft start 0-100% in 10" BY PASS Rated voltage 400 Vac three-phase selectable 380
Riello Master HE UPS MHE 400
Riello Master HE UPS MHE 400
Specifications: INPUT Rated power 400000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 564 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Sentinel Dual (High Power) UPS SDL 6500 TM
Riello Sentinel Dual (High Power) UPS SDL 6500 TM
Specifications:INPUTRated power 6500 VAVoltage 380-400-415 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Sentinel Pro UPS SEP 1000
Riello Sentinel Pro UPS SEP 1000
Specifications:INPUTRated power 1000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Sentinel Power UPS SPW 6000
Riello Sentinel Power UPS SPW 6000
Specifications:INPUTRated power 6000 VAVoltage 220-230-240 VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OU
Riello Multi Sentry UPS MST 10
Riello Multi Sentry UPS MST 10
Specifications:INPUTRated power 10000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Master HE UPS MHE 500
Riello Master HE UPS MHE 500
Specifications: INPUT Rated power 500000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 702 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Master MPS UPS MPM 60
Riello Master MPS UPS MPM 60
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 360-400-420 Vac three-phase + NRated frequen
Riello iDialog UPS IDG 400
Riello iDialog UPS IDG 400
Specifications:INPUTRated power 400 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 400 VAActive power 240 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)BATTERIES
Riello Sentinel Dual (High Power) UPS SDL 4000
Riello Sentinel Dual (High Power) UPS SDL 4000
Specifications:INPUTRated power 4000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤7%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE