INPUT
Rated power 700 VA
Voltage 220-230-240 Vac
Voltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD
Frequency 50/60 Hz
Frequency tolerance 50 Hz ± 5% / 60 Hz ± 5%
Power factor > 0.99
Current distorsion ≤7%
BY PASS
Voltage tolerance 180 - 264
Frequency tolerance Frequency selected (from ±0.Hz to ±5Hz configurable)
Number phases 1
OUTPUT and INVERTER OUTPUT
Rated power 700 VA
Active power 560 W
Number phases 1
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Frequency Can be selected: 50 Hz or 60 Hz or self-learning
Voltage distortion with distorcing load < 4%
Voltage distortion with linear load < 2%

Riello Master HP UPS MHT 250
Riello Master HP UPS MHT 250
SpecificationsINPUTRated power 250000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 352 ACurrent distorsion
Riello Master HE UPS MHE 600
Riello Master HE UPS MHE 600
Specifications: INPUT Rated power 600000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 842 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Master HE UPS MHE 500
Riello Master HE UPS MHE 500
Specifications: INPUT Rated power 500000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 702 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Sentinel Pro UPS SEP 2200 ER
Riello Sentinel Pro UPS SEP 2200 ER
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Master HP UPS MHT 200
Riello Master HP UPS MHT 200
SpecificationsINPUTRated power 200000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 281 ACurrent distorsion
Riello Master HE UPS MHE 400
Riello Master HE UPS MHE 400
Specifications: INPUT Rated power 400000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 564 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Multi Sentry UPS MSM 12
Riello Multi Sentry UPS MSM 12
Specifications: INPUT Rated power 12000 VA Voltage 230 Vac single-phase or 400 Vac three-phase + N Vac Voltage tolerance ± 20% Frequency tolerance 40/72 Hz Power factor 0.99 BY PASS Rated voltage 230 Voltage tolerance ± 15% (selectable from ± 5% to ± 25%) Rated frequency 50/60 Hz Freq
Riello Master HP UPS MHT 160
Riello Master HP UPS MHT 160
SpecificationsINPUTRated power 160000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 226 ACurrent distorsion
Riello Master MPS UPS MPT 800
Riello Master MPS UPS MPT 800
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph
Riello Sentinel Dual (High Power) UPS SDL 6000
Riello Sentinel Dual (High Power) UPS SDL 6000
Specifications:INPUTRated power 6000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE