Specifications
INPUT
Rated power 600000 VA
Voltage 400 Vac three-phase Vac
Voltage tolerance + 20% - 25%
Frequency 50/60 Hz with autorange
Frequency tolerance 45/65 Hz
Power factor 0,99
Input current 842 A
Current distorsion <3%
Soft start 0-100% in 10
BY PASS
Rated voltage 400 Vac three-phase selectable 380 and 415
Voltage tolerance ± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency 50/60 Hz (autorange)
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Rated current 842 A
Number phases 3
Back-feed protection yes
Overload capacity Inx10ms 25
OUTPUT and INVERTER OUTPUT
Rated power 600000 VA
Active power 540000 W
Number phases 3 + N
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Dynamic stability ± 5% in 5 ms
Frequency same as the input (autorange)
Voltage distortion with distorcing load <3%
Voltage distortion with linear load <1%
Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5% from front panel) with mains supply present
Inverter efficiency at rated load 95 %
Overload 125% 150% 200% of the rated current for 10' / 1' / 7

Riello Multi Sentry UPS MCT 12
Riello Multi Sentry UPS MCT 12
Specifications:INPUTRated power 12000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Master HP UPS MHT 120
Riello Master HP UPS MHT 120
SpecificationsINPUTRated power 120000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 169 ACurrent distorsion
Riello Multi Guard Industrial UPS GMI 160
Riello Multi Guard Industrial UPS GMI 160
Specifications:INPUTFrequency tolerance between 40 Hz and 72 HzPower factor >0.99BY PASSRated voltage 220-230-240 Vac, single-phase + NOUTPUT and INVERTER OUTPUTRated power 20000 VAActive power 18000 WFrequency 50 Hz / 60 HzENVIRONMENTALNoise from ≤ 52 dBA to ≤ 70 dBADATADimensions (h w d) 745 x
Riello Multi Sentry UPS MCM 20
Riello Multi Sentry UPS MCM 20
Specifications:INPUTRated power 20000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Multi Sentry UPS MST 15
Riello Multi Sentry UPS MST 15
Specifications:INPUTRated power 15000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Dual (Low Power) UPS SDH 3000
Riello Sentinel Dual (Low Power) UPS SDH 3000
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency
Riello iPlug UPS IPG 800
Riello iPlug UPS IPG 800
Specifications:INPUTRated power 800 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz with auto sensingOUTPUT and INVERTER OUTPUTRated power 800 VAActive power 480 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (+/- 1%)BAT
Riello iDialog UPS IDG 1600
Riello iDialog UPS IDG 1600
Specifications:INPUTRated power 1600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 1600 VAActive power 960 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)
Riello Master MPS UPS MPT 200
Riello Master MPS UPS MPT 200
Specifications:NPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated freq
Riello Master HP UL UPS MHT UL 100
Riello Master HP UL UPS MHT UL 100
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)100/90 %Input voltage distoration (THDi) <3 Outpu