Specifications:
INPUT
Rated power 1100 VA
Voltage 230 Vac
Frequency 50/60 Hz with autorange
Frequency tolerance ± 10Hz
OUTPUT and INVERTER OUTPUT
Rated power 1100 VA
Active power 740 W
Number phases 1
Waveform Sinewave
Frequency 50 or 60 Hz with autorange
BATTERIES
Type Maintenance-free sealed lead acid
Typical recharge time 2÷4 h

Riello Sentinel Pro UPS SEP 3000
Riello Sentinel Pro UPS SEP 3000
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Multi Sentry UPS MCM 20
Riello Multi Sentry UPS MCM 20
Specifications:INPUTRated power 20000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Sentinel Dual (High Power) UPS SDL 8000
Riello Sentinel Dual (High Power) UPS SDL 8000
Specifications:INPUTRated power 8000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Multi Sentry UPS MST 30
Riello Multi Sentry UPS MST 30
Specifications:INPUTRated power 30000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Master Industrial UPS MIM 60
Riello Master Industrial UPS MIM 60
Specifications: INPUT Rated power 60000 VA Voltage 400 Vac three-phase Vac Voltage tolerance ± 20% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0.93 Current distorsion <5% Soft start 0-100% in 10" BY PASS Rated voltage 400 Vac three-phase selectable 380
Riello Dialog Vision UPS DVR 1100
Riello Dialog Vision UPS DVR 1100
Specifications: INPUT Rated power 1100 VA Voltage 230 Vac Frequency 50/60 Hz with autorange Frequency tolerance ± 10Hz OUTPUT and INVERTER OUTPUT Rated power 1100 VA Active power 740 W Number phases 1 Waveform Sinewave Frequency 50 or 60 Hz with autorange BATTERIES Type Maintenance-fre
Riello Multi Sentry UPS MSM 15
Riello Multi Sentry UPS MSM 15
Specifications:INPUTRated power 15000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Sentinel Dual (High Power) UPS SDL 3300
Riello Sentinel Dual (High Power) UPS SDL 3300
Specifications:INPUTRated power 3300 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤7%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Sentinel Pro UPS SEP 700
Riello Sentinel Pro UPS SEP 700
Specifications:INPUTRated power 700 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Multi Sentry UPS MCT 12
Riello Multi Sentry UPS MCT 12
Specifications:INPUTRated power 12000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25