Specifications:
INPUT
Voltage 220-230-240 Vac
Frequency 50/60 Hz +/- 10 Hz
BY PASS
Voltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)
Frequency tolerance Selected frequency ±10%
OUTPUT and INVERTER OUTPUT
Rated power 20000 VA
Active power 18000 W
Waveform Sinusoidal

Riello Master HP UL UPS MHT UL 80
Riello Master HP UL UPS MHT UL 80
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)80/72 %Input voltage distoration (THDi) <3 Output
Riello Multi Sentry UPS MST 10
Riello Multi Sentry UPS MST 10
Specifications:INPUTRated power 10000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Multi Sentry UPS MCT 10
Riello Multi Sentry UPS MCT 10
Specifications:INPUTRated power 10000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Dual (High Power) UPS SDL 4000
Riello Sentinel Dual (High Power) UPS SDL 4000
Specifications:INPUTRated power 4000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤7%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Master HE UPS MHE 200
Riello Master HE UPS MHE 200
Specifications: INPUT Rated power 200000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 281 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Vision UPS VST 800
Riello Vision UPS VST 800
Specifications:INPUTRated power 800 VAVoltage 230 VacFrequency 50/60 Hz with autorangeFrequency tolerance ± 5%OUTPUT and INVERTER OUTPUTRated power 800 VAActive power 540 WNumber phases 1Waveform SinewaveFrequency 50/60 Hz with autorange
Riello Multi Sentry UPS MST 80
Riello Multi Sentry UPS MST 80
Specifications:INPUTINPUTRated power 80000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ±
Riello Multi Sentry UPS MST 100
Riello Multi Sentry UPS MST 100
Specifications:INPUTRated power 100000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.2
Riello Sentinel Dual (High Power) UPS SDL 8000 TM
Riello Sentinel Dual (High Power) UPS SDL 8000 TM
Specifications:INPUTRated power 8000 VAVoltage 380-400-415 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Master HE UPS MHE 400
Riello Master HE UPS MHE 400
Specifications: INPUT Rated power 400000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 564 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t