Specifications:
INPUT
Rated power 80000 VA
Voltage 400 Vac three-phase Vac
Voltage tolerance ± 20%
Frequency 50/60 Hz with autorange
Frequency tolerance 45/65 Hz
Power factor 0.93
Current distorsion <5%
Soft start 0-100% in 10"
BY PASS
Rated voltage 400 Vac three-phase selectable 380 and 415
Voltage tolerance ± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency 50/60 Hz (autorange)
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Number phases 3
Back-feed protection yes
Overload capacity Inx10ms 14
OUTPUT and INVERTER OUTPUT
Rated power 80000 VA
Active power 64000 W
Number phases 3 + N
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Static stability ± 1%
Dynamic stability ± 5% in 5 ms
Frequency same as the input (autorange)
Voltage distortion with distorcing load <3%
Voltage distortion with linear load 1% (rated) 2% (max)
Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5% from front panel) with mains supply present
Inverter efficiency at rated load 95% %
Overload 125% 150% 200% of the rated current for 10^ / 1^ / 7§

Riello Sentinel Power Green UPS SPH 10 ER
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 10000 VAActive power 9000 WWaveform Sinusoidal
Riello Sentinel Pro UPS SEP 700
Riello Sentinel Pro UPS SEP 700
Specifications:INPUTRated power 700 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Sentinel Dual (Low Power) UPS SDH 1500
Riello Sentinel Dual (Low Power) UPS SDH 1500
Specifications:INPUTRated power 1500 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Multi Guard UPS GMT 120
Riello Multi Guard UPS GMT 120
Specifications:INPUTFrequency tolerance between 40 Hz and 70 HzPower factor >0.99BY PASSRated voltage 380-400-415 Vac, three-phase + NOUTPUT and INVERTER OUTPUTRated power 15 kVA / 13.5 kW per module VAFrequency 50 Hz / 60 HzENVIRONMENTALSafety compliance IEC 62040-1Noise from ≤ 60 dBA to ≤ 62 d
Riello Master Industrial UPS MIM 40
Riello Master Industrial UPS MIM 40
Specifications: INPUT Rated power 40000 VA Voltage 400 Vac three-phase Vac Voltage tolerance ± 20% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0.93 Current distorsion <5% Soft start 0-100% in 120" configurable BY PASS Rated voltage 400 Vac three-phase s
Riello iPlug UPS IPG 800
Riello iPlug UPS IPG 800
Specifications:INPUTRated power 800 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz with auto sensingOUTPUT and INVERTER OUTPUTRated power 800 VAActive power 480 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (+/- 1%)BAT
Riello Sentinel Dual (High Power) UPS SDL 6500 TM
Riello Sentinel Dual (High Power) UPS SDL 6500 TM
Specifications:INPUTRated power 6500 VAVoltage 380-400-415 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Rielloi Dialog Rack UPS IDR 1200
Rielloi Dialog Rack UPS IDR 1200
Specifications:INPUTRated power 1200 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 1200 VAActive power 720 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)BATTERI
Riello Dialog Vision UPS DVR 800
Riello Dialog Vision UPS DVR 800
Specifications: INPUT Rated power 800 VA Voltage 230 Vac Frequency 50/60 Hz with autorange Frequency tolerance ± 10Hz OUTPUT and INVERTER OUTPUT Rated power 800 VA Active power 540 W Number phases 1 Waveform Sinewave Frequency 50 or 60 Hz with autorange BATTERIES Type Maintenance-free
Riello Net Power UPS NPW 800
Riello Net Power UPS NPW 800
Specifications:INPUTVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 26%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 800 VAActive power 480 WWave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 0.5%)BATTERIESType Maintenance-free sealed le