Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / Riello UPS Power Supply / Riello Multi Sentry UPS MST 120

Riello Multi Sentry UPS MST 120

Riello Multi Sentry UPS MST 120
share

Specifications:
INPUT
Rated power 120000 VA
Voltage 400 Vac three-phase + N Vac
Voltage tolerance ± 20%
Frequency tolerance 40/72 Hz
Power factor 0.99
BY PASS
Rated voltage 400
Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)
Rated frequency 50/60 Hz
Frequency tolerance ± 5% (selectable from ± 0.25% to ± 10%)
Number phases 3
OUTPUT and INVERTER OUTPUT
Rated power 120000 VA
Active power 108000 W
Output current 182 A
Number phases 3
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Static stability ± 1%
Dynamic stability ± 3% in 10 ms
Frequency 50/60 Hz selectable
Voltage distortion with distorcing load 3%
Voltage distortion with linear load 1%
Overload 125% 150% 168% of the rated current for 10' / 1' / 5"

Riello Master MPS UPS MPT 160
Riello Master MPS UPS MPT 160
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph
Riello Master HE UPS MHE 800
Riello Master HE UPS MHE 800
Specifications: INPUT Rated power 800000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 1122 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac
Riello Vision Dual UPS VSD 2200
Riello Vision Dual UPS VSD 2200
Specifications: INPUT Rated power 2200 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 2200 VA Active power 1980 W Number phases 1 Crest factor (Ipea
Riello Master HE UPS MHE 600
Riello Master HE UPS MHE 600
Specifications: INPUT Rated power 600000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 842 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Master MPS UPS MPM 80
Riello Master MPS UPS MPM 80
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 360-400-420 Vac three-phase + NRated frequen
Riello Sentinel Power Green UPS SPH 20
Riello Sentinel Power Green UPS SPH 20
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 20000 VAActive power 18000 WWaveform Sinusoidal
Riello Multi Sentry UPS MCM 20
Riello Multi Sentry UPS MCM 20
Specifications:INPUTRated power 20000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Master HE UPS MHE 500
Riello Master HE UPS MHE 500
Specifications: INPUT Rated power 500000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 702 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Master HP UL UPS MHT UL 65
Riello Master HP UL UPS MHT UL 65
Specifications: INPUT Voltage 480 Vac tolerance + N Vac Frequency 45 ÷ 65 Hz Power factor > 0,99 Current distorsion <3% Soft start 0 ÷ 100% in 30" OUTPUT Rated power 65000 VA Active power 58500 W
Riello Master HP UL UPS MHT UL 250
Riello Master HP UL UPS MHT UL 250
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)250/225 %Input voltage distoration (THDi) <3 Outpu