Riello Master FC400 UPS MFC 120

Riello Master FC400 UPS MFC 120
share

Specifications:
SKU MFC120
Power 120kVA/96kW
Runtime Add external battery extension
Input Connection Hardwired terminals
Input Voltage 380/400/415Vac 3phase, 45-65Hz
Output Connection Hardwired terminals
Output Voltage 208Vac 3phase+N +/-1%, 400Hz +/- 0.05%
Dimensions (WxDxH) 550x740x1200mm
Nett Weight 330Kg
Delivery Time Typically within 15-20 working days
Maintenance Plan 4 clock hours, 8 and 12 working hours, remote monitoring
Warranty 36 months (extended available)

Riello Multi Sentry UPS MST 120
Riello Multi Sentry UPS MST 120
Specifications:INPUTRated power 120000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.2
Riello iDialog UPS IDG 1600
Riello iDialog UPS IDG 1600
Specifications:INPUTRated power 1600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 1600 VAActive power 960 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)
Riello Vision Dual UPS VSD 2200
Riello Vision Dual UPS VSD 2200
Specifications: INPUT Rated power 2200 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 2200 VA Active power 1980 W Number phases 1 Crest factor (Ipea
Riello Sentinel Pro UPS SEP 2200 ER
Riello Sentinel Pro UPS SEP 2200 ER
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Net Power UPS NPW 600
Riello Net Power UPS NPW 600
Specifications:INPUTVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 26%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WWave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 0.5%)BATTERIESType Maintenance-free sealed le
Riello Master HE UPS MHE 200
Riello Master HE UPS MHE 200
Specifications: INPUT Rated power 200000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 281 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Master HP UL UPS MHT UL 200
Riello Master HP UL UPS MHT UL 200
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)200/180 %Input voltage distoration (THDi) <3 Outpu
Riello Sentinel Power Green UPS SPH 15
Riello Sentinel Power Green UPS SPH 15
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 15000 VAActive power 13500 WWaveform Sinusoidal
Riello Sentinel Dual (High Power) UPS SDL 10000
Riello Sentinel Dual (High Power) UPS SDL 10000
Specifications:INPUTRated power 10000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERT
Riello Master HP UL UPS MHT UL 160
Riello Master HP UL UPS MHT UL 160
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)160/144 %Input voltage distoration (THDi) <3 Outpu