Specifications:
SKU MFC120
Power 120kVA/96kW
Runtime Add external battery extension
Input Connection Hardwired terminals
Input Voltage 380/400/415Vac 3phase, 45-65Hz
Output Connection Hardwired terminals
Output Voltage 208Vac 3phase+N +/-1%, 400Hz +/- 0.05%
Dimensions (WxDxH) 550x740x1200mm
Nett Weight 330Kg
Delivery Time Typically within 15-20 working days
Maintenance Plan 4 clock hours, 8 and 12 working hours, remote monitoring
Warranty 36 months (extended available)

Riello Multi Sentry UPS MST 80
Riello Multi Sentry UPS MST 80
Specifications:INPUTINPUTRated power 80000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ±
Riello Sentinel Dual (Low Power) UPS SDH 3000
Riello Sentinel Dual (Low Power) UPS SDH 3000
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency
Riello Master HP UPS MHT 160
Riello Master HP UPS MHT 160
SpecificationsINPUTRated power 160000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 226 ACurrent distorsion
Riello Multi Sentry UPS MST 12
Riello Multi Sentry UPS MST 12
Specifications:INPUTRated power 12000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello iDialog UPS IDG 400
Riello iDialog UPS IDG 400
Specifications:INPUTRated power 400 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 400 VAActive power 240 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)BATTERIES
Riello Master HE UPS MHE 600
Riello Master HE UPS MHE 600
Specifications: INPUT Rated power 600000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 842 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Master HP UL UPS MHT UL 65
Riello Master HP UL UPS MHT UL 65
Specifications: INPUT Voltage 480 Vac tolerance + N Vac Frequency 45 ÷ 65 Hz Power factor > 0,99 Current distorsion <3% Soft start 0 ÷ 100% in 30" OUTPUT Rated power 65000 VA Active power 58500 W
Riello Vision UPS VST 1100
Riello Vision UPS VST 1100
Specifications:INPUTRated power 1100 VAVoltage 230 VacFrequency 50/60 Hz with autorangeFrequency tolerance ± 5%OUTPUT and INVERTER OUTPUTRated power 1100 VAActive power 880 WNumber phases 1Waveform SinewaveFrequency 50/60 Hz with autorangeBATTERIESType Maintenance-free sealed lead acidTypical recha
Rielloi Dialog Rack UPS IDR 600
Rielloi Dialog Rack UPS IDR 600
Specifications:INPUTRated power 600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)BATTERIES
Riello Master MPS UPS MPT 60
Riello Master MPS UPS MPT 60
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph