Specifications:
INPUT
Rated power 2200 VA
Voltage 220-230-240 Vac
Voltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD
Frequency 50/60 Hz
Frequency tolerance 50 Hz ± 5% / 60 Hz ± 5%
Power factor > 0.99
Current distorsion ≤7%
BY PASS
Voltage tolerance 200 - 253
Frequency tolerance Frequency selected (from ±0.Hz to ±5Hz configurable)
Number phases 1
OUTPUT and INVERTER OUTPUT
Rated power 2200 VA
Active power 1980 W
Number phases 1
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Frequency Can be selected: 50 Hz or 60 Hz or self-learning
Voltage distortion with distorcing load < 4%
Voltage distortion with linear load < 2%

Riello Multi Sentry UPS MST 15
Riello Multi Sentry UPS MST 15
Specifications:INPUTRated power 15000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Power Green UPS SPM 6
Riello Sentinel Power Green UPS SPM 6
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 6000 VAActive power 5400 WWaveform SinusoidalOVERLOAD TIMES
Riello Master HP UPS MHT 120
Riello Master HP UPS MHT 120
SpecificationsINPUTRated power 120000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 169 ACurrent distorsion
Riello Multi Sentry UPS MST 80
Riello Multi Sentry UPS MST 80
Specifications:INPUTINPUTRated power 80000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ±
Riello Multi Sentry UPS MST 100
Riello Multi Sentry UPS MST 100
Specifications:INPUTRated power 100000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.2
Riello Master MPS UPS MPT 200
Riello Master MPS UPS MPT 200
Specifications:NPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated freq
Riello iDialog UPS IDG 400
Riello iDialog UPS IDG 400
Specifications:INPUTRated power 400 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 400 VAActive power 240 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)BATTERIES
Riello Master HP UL UPS MHT UL 80
Riello Master HP UL UPS MHT UL 80
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)80/72 %Input voltage distoration (THDi) <3 Output
Riello iDialog UPS IDG 1600
Riello iDialog UPS IDG 1600
Specifications:INPUTRated power 1600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 1600 VAActive power 960 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)
Riello Master HP UPS MHT 400
Riello Master HP UPS MHT 400
SpecificationsINPUTRated power 400000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 564 ACurrent distorsion