Powerware 9170 Online UPS PW6S6K

Powerware 9170 Online UPS PW6S6K
share

Power Description
Power Rating (VA) 6000
Rated Load Capacity (Watts) 5000
Standard Warranty 2 years parts; 90 days onsite labor
Optional Warranties Cover parts and labor up to 5 years
Electrical Input
Input Voltage 208-240 neutral required
Input Connection Hardwired hardwired terminal
Electrical Output
Output Voltage 208-240/120
Output Connection Hardwired hardwired terminal
Battery Backup
Battery Runtime Minutes (Full Load) 6.5
Battery Runtime Minutes (Half Load) 16
Optional Extended Run Batteries ASY-0529

Powerware Plus18 UPS Model 12
Powerware Plus18 UPS Model 12
Specifications: Input Frequency Range 45-65 Hz Power Factor 0.95 Typical at full load Output Voltage Regulation Better than +/- 3% Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load)Transient Response Less than 5% for 100% load, step full recovery within 1/4 cycl
Powerware 9305 UPS PW9305-20I-N
Powerware 9305 UPS PW9305-20I-N
Rating 20 kVA Capacity (VA/Watts) 20 kVA/14 kW Dimensions WxDxH (mm) 520x788x1530 Weight (kg) 400Input connection Hardwired Output connection HardwiredTypical runtime (Full load) 12 min (Half load) 30 min
Powerware 9125 Rackmount UPS 91252200aRM
Powerware 9125 Rackmount UPS 91252200aRM
Specifications:Rating 2200VA Capacity (VA/Watts) 2200/1540 Dimensions WxDxH (mm) 432X607X89 Weight (kg) 35 Input Connection IEC320/10AOutput Connection 2xAS3112 10A 2xIEC320 10AOperationalNominal input voltage (Vac) 220/230/240 VacInput voltage range 160-288 VAC
Powerware BPIV Industrial UPS 30 kVA/27 kw
Powerware BPIV Industrial UPS 30 kVA/27 kw
Descriptions:The BPIV delivers enhanced backup power, power quality, and system reliability with the highest efficiency ratings of any online UPS in the 10-30 kVA range for industrial equipment. Powerware Industrial UPS systems offer cost savings with the best power protection.
Powerware BPIII 300 Industrial UPS 225-300 kVA
Powerware BPIII 300 Industrial UPS 225-300 kVA
Specifications:Input SpecificationsFrequency range: (60 Hz) 57-63 HzSurge protection: Meets ANSI C62.41Category A & B: EN 50091-2, and EN 50082-2Power factor: 0.95 typical at full load with input filterInput currentdistortion: less than 7% with input filterOutput SpecificationsVoltage THD: Less than
Powerware 9 Prestige UPS Model 1500VA/1050W EXT
Powerware 9 Prestige UPS Model 1500VA/1050W EXT
Specifications: Rating: 650-6000 VA Input Voltage: 120 Vac; 200–240 Vac Output Voltage: 120 Vac; 120/208 120/240 Vac Frequency: 50/60 Hz Configuration: Modular; rack-mount and cabinet
Powerware 3110 UPS PW3110 550
Powerware 3110 UPS PW3110 550
Descriptions:Ideal for PC-based applications, the Powerware 3110 provides affordable protection in a sleek, well-designed unit that can fit undera desk or can be wall-mounted.
Powerware BPIII HE UPS 62.5 kVA/50 kw
Powerware BPIII HE UPS 62.5 kVA/50 kw
Specifications:Configuration: 3-Phase, 3 wire plus groundRange Nominal +10%, –15%Frequency range Nominal ±3 Hz (60 Hz)Power factor Minimum 0.9 with filterPower walk-in 3-60 seconds to full loadInput current 10% THD under nominal conditions distortion with filterTransient protection 6kV OC, 3 kV S
Powerware 9120 UPS PW9120 3000
Powerware 9120 UPS PW9120 3000
Descriptions:The Powerware 9120 UPS is designed for those applicationsthat need maximum protection in the 700 VA – 3 kVA range.With its high-frequency, doubleconversion online topology, providingnonstop clean sine wave power, advanced communicationsand space-saving tower design, the Powerware 9120
Powerware Plus36 UPS Model 24
Powerware Plus36 UPS Model 24
Specifications: Input Frequency Range 45-65 Hz Power Factor 0.95 Typical at full load Output Voltage Regulation Better than +/- 2% Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load) Transient Response Less than 5% for 100% load, step full recovery within 1/4 cycl