Home / Products / UPS Power Supply / Powerware UPS Power Supply / Powerware 9120 UPS PW9120 2000i

Powerware 9120 UPS PW9120 2000i

Powerware 9120 UPS PW9120 2000i
share

Descriptions:
The Powerware 9120 UPS is designed for those applications
that need maximum protection in the 700 VA – 3 kVA range.
With its high-frequency, doubleconversion online topology, providing
nonstop clean sine wave power, advanced communications
and space-saving tower design, the Powerware 9120 is the ideal solution for networks,
web servers, telecommunications applications and other
critical electronic equipment.

Powerware 5119 Rackmount UPS PW5119 2000RM
Powerware 5119 Rackmount UPS PW5119 2000RM
Specifications:Electrical InputVoltage 120 and 230 VAC NominalOn Line Voltage Range -30%, +20% for nominal voltages; user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)Nominal Input Frequency 50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)Frequency Tolerance No
Powerware BPIV Industrial UPS 15 kVA/13.5 kw
Powerware BPIV Industrial UPS 15 kVA/13.5 kw
Descriptions:The BPIV delivers enhanced backup power, power quality, and system reliability with the highest efficiency ratings of any online UPS in the 10-30 kVA range for industrial equipment. Powerware Industrial UPS systems offer cost savings with the best power protection.
Powerware 5119 Rackmount UPS PW5119 3000iRM
Powerware 5119 Rackmount UPS PW5119 3000iRM
Specifications:Electrical InputVoltage 120 and 230 VAC NominalOn Line Voltage Range -30%, +20% for nominal voltages; user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)Nominal Input Frequency 50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)Frequency Tolerance No
Powerware 5119 UPS PW5119 2400
Powerware 5119 UPS PW5119 2400
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Powerware 9170 Online UPS PW12S15K
Powerware 9170 Online UPS PW12S15K
Specifications:Technical InformationPlug/Connector Type HardwiredReceptacles HardwiredPower DescriptionLoad Capacity 15 kVA/10.50 kWInput Voltage 110 V AC/220 V ACInput Voltage Range 120 V AC/208 V AC/220 V ACOutput Voltage 120 V AC/208 V AC/240 V ACFrequency 50 Hz/60 HzWaveform Type Sine WaveScalab
Powerware 9170 Online UPS PW6S9K
Powerware 9170 Online UPS PW6S9K
Specifications:Technical InformationPlug/Connector Type HardwiredReceptacles HardwiredPower DescriptionLoad Capacity 9 kVAInput Voltage 110 V AC220 V ACInput Voltage Range 100 V AC to 276 V ACOutput Voltage 120 V AC208 V AC240 V ACFrequency 50 Hz60 HzPower Range 9 kVA to 9 kVA
Powerware 9305 UPS PW9305-10I-N
Powerware 9305 UPS PW9305-10I-N
Specifications:Rating 10 kVA Capacity (VA/Watts) 10 / 7Dimensions WxDxH (mm) 400x750x700 Weight (kg) 180 Input connection Hardwired Output connection HardwiredTypical runtime (Full load) 14 min (Half load) 7 min
Powerware BPII HE UPS 10 kVA/8 kw
Powerware BPII HE UPS 10 kVA/8 kw
Descriptions:Balanced Power II HE and Balanced Power II-S HE (BPII HE and BPII-S HE) offer the reliability of true online technology utilizing digital signal processing (DSP) control and monitoring. In addition, the BPII HE and BPII-S HE use the patented technology of an inverter software harmonic c
Powerware 9 Prestige UPS Model 1000VA/700W
Powerware 9 Prestige UPS Model 1000VA/700W
Specifications: Rating: 650-6000 VA Input Voltage: 120 Vac; 200–240 Vac Output Voltage: 120 Vac; 120/208 120/240 Vac Frequency: 50/60 Hz Configuration: Modular; rack-mount and cabinet
Powerware Plus36 UPS Model 36
Powerware Plus36 UPS Model 36
Specifications: Input Frequency Range 45-65 Hz Power Factor 0.95 Typical at full load Output Voltage Regulation Better than +/- 2% Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load) Transient Response Less than 5% for 100% load, step full recovery within 1/4 cycl