Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / Riello UPS Power Supply / Riello Master HE UPS MHE 100

Riello Master HE UPS MHE 100

Riello Master HE UPS MHE 100
share

Specifications:
INPUT
Rated power 100000 VA
Voltage 400 Vac three-phase Vac
Voltage tolerance + 20% - 25%
Frequency 50/60 Hz with autorange
Frequency tolerance 45/65 Hz
Power factor 0,99
Input current 141 A
Current distorsion <3%
Soft start 0-100% in 10
BY PASS
Rated voltage 400 Vac three-phase selectable 380 and 415
Voltage tolerance ± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency 50/60 Hz (autorange)
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Rated current 141 A
Number phases 3
Back-feed protection yes
Overload capacity Inx10ms 14
OUTPUT and INVERTER OUTPUT
Rated power 100000 VA
Active power 100000 W
Number phases 3 + N
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Dynamic stability ± 5% in 5 ms
Frequency same as the input (autorange)
Voltage distortion with distorcing load <3%
Voltage distortion with linear load <1%
Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5% from front panel) with mains supply present
Overload 125% 150% 200% of the rated current for 10' / 1' / 7

Riello Multi Sentry UPS MSM 12
Riello Multi Sentry UPS MSM 12
Specifications: INPUT Rated power 12000 VA Voltage 230 Vac single-phase or 400 Vac three-phase + N Vac Voltage tolerance ± 20% Frequency tolerance 40/72 Hz Power factor 0.99 BY PASS Rated voltage 230 Voltage tolerance ± 15% (selectable from ± 5% to ± 25%) Rated frequency 50/60 Hz Freq
Riello Multi Sentry UPS MCT 15
Riello Multi Sentry UPS MCT 15
Specifications:INPUTRated power 15000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Master MPS UPS MPT 15
Riello Master MPS UPS MPT 15
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated fre
Riello Multi Sentry UPS MCM 20
Riello Multi Sentry UPS MCM 20
Specifications:INPUTRated power 20000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Sentinel Pro UPS SEP 2200
Riello Sentinel Pro UPS SEP 2200
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Sentinel Dual (Low Power) UPS SDH 1500
Riello Sentinel Dual (Low Power) UPS SDH 1500
Specifications:INPUTRated power 1500 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Master MPS UPS MPT 200
Riello Master MPS UPS MPT 200
Specifications:NPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated freq
Riello Vision Dual UPS VSD 1500
Riello Vision Dual UPS VSD 1500
Specifications: INPUT Rated power 1500 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 1500 VA Active power 1350 W Number phases 1 Crest factor (Ipea
Riello Sentinel Power UPS SPW 6000
Riello Sentinel Power UPS SPW 6000
Specifications:INPUTRated power 6000 VAVoltage 220-230-240 VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OU
Riello Vision Dual UPS VSD 3000 ER
Riello Vision Dual UPS VSD 3000 ER
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacFrequency 50/60 Hz with automatic selectionFrequency tolerance ± 5HzPower factor > 0,98Current distorsion < 7%OUTPUT and INVERTER OUTPUTRated power 3000 VAActive power 2400 WNumber phases 1Crest factor (Ipeak/Irms) 2,5:1Wave form on batt