Riello Master HP UPS MHT 100

Riello Master HP UPS MHT 100
share

Specifications
INPUT
Rated power 100000 VA
Voltage 400 Vac three-phase Vac
Voltage tolerance + 20% - 25%
Frequency 50/60 Hz with autorange
Frequency tolerance 45/65 Hz
Power factor 0,99
Input current 141 A
Current distorsion <3%
Soft start 0-100% in 10
BY PASS
Rated voltage 400 Vac three-phase selectable 380 and 415
Voltage tolerance ± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency 50/60 Hz (autorange)
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Rated current 141 A
Number phases 3
Back-feed protection yes
Overload capacity Inx10ms 14
OUTPUT and INVERTER OUTPUT
Rated power 100000 VA
Active power 90000 W
Number phases 3 + N
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Dynamic stability ± 5% in 5 ms
Frequency same as the input (autorange)
Voltage distortion with distorcing load <3%
Voltage distortion with linear load <1%
Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5% from front panel) with mains supply present
Overload 125% 150% 200% of the rated current for 10' / 1' / 7

Riello Master HP UPS MHT 500
Riello Master HP UPS MHT 500
SpecificationsINPUTRated power 500000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 702 ACurrent distorsion
Riello Sentinel Pro UPS SEP 2200 ER
Riello Sentinel Pro UPS SEP 2200 ER
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Master HE UPS MHE 800
Riello Master HE UPS MHE 800
Specifications: INPUT Rated power 800000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 1122 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac
Riello Master HP UL UPS MHT UL 200
Riello Master HP UL UPS MHT UL 200
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)200/180 %Input voltage distoration (THDi) <3 Outpu
Riello Master HP UPS MHT 200
Riello Master HP UPS MHT 200
SpecificationsINPUTRated power 200000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 281 ACurrent distorsion
Riello Master MPS UPS MPT 15
Riello Master MPS UPS MPT 15
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated fre
Riello Master HP UPS MHT 250
Riello Master HP UPS MHT 250
SpecificationsINPUTRated power 250000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 352 ACurrent distorsion
Riello Multi Sentry UPS MCM 20
Riello Multi Sentry UPS MCM 20
Specifications:INPUTRated power 20000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Sentinel Power Green UPS SPM 6
Riello Sentinel Power Green UPS SPM 6
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 6000 VAActive power 5400 WWaveform SinusoidalOVERLOAD TIMES
Riello Sentinel Power UPS SPT 8000
Riello Sentinel Power UPS SPT 8000
Specifications:INPUTRated power 8000 VAVoltage 220-230-240 Vac single-phase or 380-400-415 Vac three-phase with neutral VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequ