Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / Riello UPS Power Supply / Riello Multi Guard UPS GMT 120

Riello Multi Guard UPS GMT 120

Riello Multi Guard UPS GMT 120
share

Specifications:
INPUT
Frequency tolerance between 40 Hz and 70 Hz
Power factor >0.99
BY PASS
Rated voltage 380-400-415 Vac, three-phase + N
OUTPUT and INVERTER OUTPUT
Rated power 15 kVA / 13.5 kW per module VA
Frequency 50 Hz / 60 Hz
ENVIRONMENTAL
Safety compliance IEC 62040-1
Noise from ≤ 60 dBA to ≤ 62 dBA

Riello Master HP UPS MHT 500
Riello Master HP UPS MHT 500
SpecificationsINPUTRated power 500000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 702 ACurrent distorsion
Riello Sentinel Pro UPS SEP 700
Riello Sentinel Pro UPS SEP 700
Specifications:INPUTRated power 700 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello iDialog UPS IDG 1600
Riello iDialog UPS IDG 1600
Specifications:INPUTRated power 1600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 1600 VAActive power 960 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)
Riello Master MPS UPS MPT 80
Riello Master MPS UPS MPT 80
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph
Riello Sentinel Pro UPS SEP 1500
Riello Sentinel Pro UPS SEP 1500
Specifications:INPUTRated power 1500 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Master HE UPS MHE 800
Riello Master HE UPS MHE 800
Specifications: INPUT Rated power 800000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 1122 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac
Riello Master HE UPS MHE 300
Riello Master HE UPS MHE 300
Specifications: INPUT Rated power 300000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 423 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Sentinel Power UPS SPT 6500
Riello Sentinel Power UPS SPT 6500
Specifications:INPUTRated power 6500 VAVoltage 220-230-240 Vac single-phase or 380-400-415 Vac three-phase with neutral VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequ
Riello iPlug UPS IPG 600
Riello iPlug UPS IPG 600
Specifications:INPUTRated power 600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz with auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (+/- 1%)
Riello Sentinel Dual (High Power) UPS SDL 5000
Riello Sentinel Dual (High Power) UPS SDL 5000
Specifications:INPUTRated power 5000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE