Specifications:
INPUT
Rated power 600 VA
Voltage 220-240 Vac
Voltage tolerance 230 Vac (+ 20 / - 25%)
Frequency 50/60 Hz with auto sensing
OUTPUT and INVERTER OUTPUT
Rated power 600 VA
Active power 360 W
Number phases 1
Wave form on battery Pseudo sinewave
Frequency on battery operation 50 or 60 Hz (+/- 1%)

Riello iDialog UPS IDG 1600
Riello iDialog UPS IDG 1600
Specifications:INPUTRated power 1600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 1600 VAActive power 960 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)
Riello Vision UPS VST 1500
Riello Vision UPS VST 1500
Specifications: INPUT Rated power 1500 VA Voltage 230 Vac Frequency 50/60 Hz with autorange Frequency tolerance ± 5% OUTPUT and INVERTER OUTPUT Rated power 1500 VA Active power 1200 W Number phases 1 Waveform Sinewave Frequency 50/60 Hz with autorange BATTERIES Type Maintenance-free se
Riello Master HE UPS MHE 100
Riello Master HE UPS MHE 100
Specifications:INPUTRated power 100000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 141 ACurrent distorsion
Riello iDialog UPS IDG 600
Riello iDialog UPS IDG 600
Specifications:INPUTRated power 600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)
Riello Net Power UPS NPW 2000
Riello Net Power UPS NPW 2000
Specifications: NPUT Rated power 2000 VA Voltage 220-240 Vac Voltage tolerance 230 Vac (+ 20 / - 26%) Frequency 50/60 Hz auto sensing OUTPUT and INVERTER OUTPUT Rated power 2000 VA Active power 1200 W Wave form on battery Pseudo sinewave Frequency on battery operation 50 or 60 Hz (± 0.5%)
Riello Vision Dual UPS VSD 3000
Riello Vision Dual UPS VSD 3000
Specifications: INPUT Rated power 3000 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 3000 VA Active power 2700 W Number phases 1 Crest factor (Ipea
Riello Master HP UPS MHT 600
Riello Master HP UPS MHT 600
SpecificationsINPUTRated power 600000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 842 ACurrent distorsion
Riello Master HP UL UPS MHT UL 160
Riello Master HP UL UPS MHT UL 160
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)160/144 %Input voltage distoration (THDi) <3 Outpu
Riello Multi Sentry UPS MCT 20
Riello Multi Sentry UPS MCT 20
Specifications:INPUTRated power 20000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Power Green UPS SPH 20
Riello Sentinel Power Green UPS SPH 20
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 20000 VAActive power 18000 WWaveform Sinusoidal