Riello Sentinel Pro UPS SEP 3000

Riello Sentinel Pro UPS SEP 3000
share

Specifications:
INPUT
Rated power 3000 VA
Voltage 220-230-240 Vac
Voltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD
Frequency 50/60 Hz
Frequency tolerance 50 Hz ± 5% / 60 Hz ± 5%
Power factor > 0.99
Current distorsion ≤7%
BY PASS
Voltage tolerance 180 - 264
Frequency tolerance Frequency selected (from ±0.Hz to ±5Hz configurable)
Number phases 1
OUTPUT and INVERTER OUTPUT
Rated power 3000 VA
Active power 2400 W
Number phases 1
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Frequency Can be selected: 50 Hz or 60 Hz or self-learning
Voltage distortion with distorcing load < 4%
Voltage distortion with linear load < 2%

Riello Dialog Vision UPS DVR 800
Riello Dialog Vision UPS DVR 800
Specifications: INPUT Rated power 800 VA Voltage 230 Vac Frequency 50/60 Hz with autorange Frequency tolerance ± 10Hz OUTPUT and INVERTER OUTPUT Rated power 800 VA Active power 540 W Number phases 1 Waveform Sinewave Frequency 50 or 60 Hz with autorange BATTERIES Type Maintenance-free
Riello Master HP UL UPS MHT UL 65
Riello Master HP UL UPS MHT UL 65
Specifications: INPUT Voltage 480 Vac tolerance + N Vac Frequency 45 ÷ 65 Hz Power factor > 0,99 Current distorsion <3% Soft start 0 ÷ 100% in 30" OUTPUT Rated power 65000 VA Active power 58500 W
Riello Multi Sentry UPS MCM 15
Riello Multi Sentry UPS MCM 15
Specifications:INPUTRated power 15000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Multi Sentry UPS MCM 12
Riello Multi Sentry UPS MCM 12
Specifications:INPUTRated power 12000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Master Industrial UPS MIM 40
Riello Master Industrial UPS MIM 40
Specifications: INPUT Rated power 40000 VA Voltage 400 Vac three-phase Vac Voltage tolerance ± 20% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0.93 Current distorsion <5% Soft start 0-100% in 120" configurable BY PASS Rated voltage 400 Vac three-phase s
Riello Multi Sentry UPS MST 120
Riello Multi Sentry UPS MST 120
Specifications:INPUTRated power 120000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.2
Riello Multi Sentry UPS MCM 20
Riello Multi Sentry UPS MCM 20
Specifications:INPUTRated power 20000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Master MPS UPS MPT 20
Riello Master MPS UPS MPT 20
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated fre
Riello Dialog Vision UPS DVR 500
Riello Dialog Vision UPS DVR 500
Specifications: INPUT Rated power 500 VA Voltage 230 Vac Frequency 50/60 Hz with autorange Frequency tolerance ± 10Hz OUTPUT and INVERTER OUTPUT Rated power 500 VA Active power 335 W Number phases 1 Waveform Sinewave Frequency 50 or 60 Hz with autorange BATTERIES Type Maintenance-free
Riello Sentinel Dual (High Power) UPS SDL 8000 TM
Riello Sentinel Dual (High Power) UPS SDL 8000 TM
Specifications:INPUTRated power 8000 VAVoltage 380-400-415 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE