Specifications:
INPUT
Rated power 100000 VA
Voltage 400 Vac three-phase + N Vac
Voltage tolerance ± 20%
Frequency tolerance 40/72 Hz
Power factor 0.99
BY PASS
Rated voltage 400
Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)
Rated frequency 50/60 Hz
Frequency tolerance ± 5% (selectable from ± 0.25% to ± 10%)
Number phases 3
OUTPUT and INVERTER OUTPUT
Rated power 100000 VA
Active power 90000 W
Output current 145 A
Number phases 3
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Static stability ± 1%
Dynamic stability ± 3% in 10 ms
Frequency 50/60 Hz selectable
Voltage distortion with distorcing load 3%
Voltage distortion with linear load 1%
Overload 125% 150% 168% of the rated current for 10' / 1' / 5

Riello Multi Sentry UPS MST 15
Riello Multi Sentry UPS MST 15
Specifications:INPUTRated power 15000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Pro UPS SEP 2200
Riello Sentinel Pro UPS SEP 2200
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Sentinel Power UPS SPT 6500
Riello Sentinel Power UPS SPT 6500
Specifications:INPUTRated power 6500 VAVoltage 220-230-240 Vac single-phase or 380-400-415 Vac three-phase with neutral VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequ
Riello Master MPS UPS MPT 160
Riello Master MPS UPS MPT 160
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph
Riello Master HP UPS MHT 100
Riello Master HP UPS MHT 100
SpecificationsINPUTRated power 100000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 141 ACurrent distorsion
Riello Multi Sentry UPS MSM 12
Riello Multi Sentry UPS MSM 12
Specifications: INPUT Rated power 12000 VA Voltage 230 Vac single-phase or 400 Vac three-phase + N Vac Voltage tolerance ± 20% Frequency tolerance 40/72 Hz Power factor 0.99 BY PASS Rated voltage 230 Voltage tolerance ± 15% (selectable from ± 5% to ± 25%) Rated frequency 50/60 Hz Freq
Riello Multi Sentry UPS MCT 15
Riello Multi Sentry UPS MCT 15
Specifications:INPUTRated power 15000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Dual (Low Power) UPS SDH 3000 ER
Riello Sentinel Dual (Low Power) UPS SDH 3000 ER
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency
Riello Sentinel Dual (High Power) UPS SDL 8000 TM
Riello Sentinel Dual (High Power) UPS SDL 8000 TM
Specifications:INPUTRated power 8000 VAVoltage 380-400-415 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello iPlug UPS IPG 600
Riello iPlug UPS IPG 600
Specifications:INPUTRated power 600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz with auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (+/- 1%)