Specification:
AC Input Rating
+15% ~ -25%
Power: Rated 1kVA : 1kW Generator 208Y / 120VAC
THD (reflected current):4% typical (100% load) 7% typical (50%load)
3-phase, 4-wire, plus ground
Frequency: 60Hz (±5%)
AC Output Rating
3-phase, 4-wire, plus ground 208Y / 120 VAC
Output power factor rating: 0.8 ~ 1.0 Lag (within output kW rating)
Frequency: 60Hz ± 0.01% (free running)
Voltage accuracy: ± 1%

Mitsubishi 9800AD Series UPS 375KVA/337KW
Mitsubishi 9800AD Series UPS 375KVA/337KW
Specification:AC Input Rating-15% ~ +15%Power: Rated kVA at 1:1.1 ratio480 VAC (600 VAC usinginput transformer)THD (reflected current):6% typical (100% load) 9% typical (50% load)3-phase, 4-wire, plus ground(Bypass: 4-wire, Rectifier: 3-wire)Frequency: 60Hz (±5%)480Y/277 VAC
Mitsubishi 7011A Series UPS 12KVA
Mitsubishi 7011A Series UPS 12KVA
Description:Design: On-Line Double Conversion with Extra Wide Input Voltage and Frequency WindowPower Rating: 6, 8, 10, 12 kVAVoltage Options: Input: 120/208 or 120/240 VAC Single Phase Output: 120/208 or 120/240 VAC Single Phase
Mitsubishi 9700 Series UPS 100KVA/80KW
Mitsubishi 9700 Series UPS 100KVA/80KW
SPECIFICATION:AC INPUT CHARACTERISTICSConfiguration 3 phase, 3 wireVoltage 208V +10% ~ -15%Input Power Factor 0.98 TypicalFrequency 60 Hz ±5%Reflected Current THD 3% max. at 100% load; 5% max. at 50% loadSTATIC BYPASS INPUTConfiguration 3 phase, 3 or 4 wireVoltage 120/208V ±10%Frequency 60 Hz (±3
Mitsubishi 2033D Series UPS 50KVA/40KW
Mitsubishi 2033D Series UPS 50KVA/40KW
Description:The2033D series UPS is available in capacities of 30 and 50KVA. They are designed for stand-alone operation. Use of customized IGBTs results in untra-high performance for the Series 2033D UPS. It is designed to protect critical loads in a variety of environments. Its light weight and sma
Mitsubishi 9900A Series UPS 150kVA
Mitsubishi 9900A Series UPS 150kVA
Description:The 9900 Series UPS incorporates the newest IGBT technology in an UPS. This IGBT technology is used in the rectifier/converter, DC/DC chopper, and the inverter sections of the UPS. By using this new IGBT technology the 9900's double-conversion topology provides an AC/DC/AC efficiency of
Mitsubishi 9900C Series UPS 1050KVA/1000KW
Mitsubishi 9900C Series UPS 1050KVA/1000KW
Description: Design: Double Conversion On-Line Topology Power Rating: 1050 kVA Voltage: Input: 480V; Output: 480V
Mitsubishi 9900A Series UPS 100kVA
Mitsubishi 9900A Series UPS 100kVA
Description:The 9900 Series UPS incorporates the newest IGBT technology in an UPS. This IGBT technology is used in the rectifier/converter, DC/DC chopper, and the inverter sections of the UPS. By using this new IGBT technology the 9900's double-conversion topology provides an AC/DC/AC efficiency of
Mitsubishi 1100B Series UPS 10KVA
Mitsubishi 1100B Series UPS 10KVA
Description:Design: Double Conversion On-Line TopologyPower Ratings: 10, 20, 30, 40, 50, 60, 70, & 80 kVAVoltage Options: Input: 208/120V; Output: 208/120VDesign Features:* Modular Design* 20 kVA and Above Can be Operated as a Capacity System or as N+1Available for All Models* Compact Design: 31.5"W
Mitsubishi 7011A Series UPS 6KVA
Mitsubishi 7011A Series UPS 6KVA
Description:Design: On-Line Double Conversion with Extra Wide Input Voltage and Frequency WindowPower Rating: 6, 8, 10, 12 kVAVoltage Options: Input: 120/208 or 120/240 VAC Single Phase Output: 120/208 or 120/240 VAC Single Phase
Mitsubishi 9900A Series UPS 80kVA
Mitsubishi 9900A Series UPS 80kVA
Description:The 9900 Series UPS incorporates the newest IGBT technology in an UPS. This IGBT technology is used in the rectifier/converter, DC/DC chopper, and the inverter sections of the UPS. By using this new IGBT technology the 9900's double-conversion topology provides an AC/DC/AC efficiency of