Specifications:
INPUT
Voltage 220-240 Vac
Voltage tolerance 230 Vac (+ 20 / - 26%)
Frequency 50/60 Hz auto sensing
OUTPUT and INVERTER OUTPUT
Rated power 800 VA
Active power 480 W
Wave form on battery Pseudo sinewave
Frequency on battery operation 50 or 60 Hz (± 0.5%)
BATTERIES
Type Maintenance-free sealed lead-acid
Typical recharge time 2÷4 h

Riello Master HP UPS MHT 200
Riello Master HP UPS MHT 200
SpecificationsINPUTRated power 200000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 281 ACurrent distorsion
Riello Sentinel Power Green UPS SPH 20
Riello Sentinel Power Green UPS SPH 20
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 20000 VAActive power 18000 WWaveform Sinusoidal
Riello Sentinel Dual (High Power) UPS SDL 8000
Riello Sentinel Dual (High Power) UPS SDL 8000
Specifications:INPUTRated power 8000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Sentinel Power Green UPS SPH 10
Riello Sentinel Power Green UPS SPH 10
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 10000 VAActive power 9000 WWaveform SinusoidalOVERLOAD TIME
Riello Sentinel Power UPS SPW 6000
Riello Sentinel Power UPS SPW 6000
Specifications:INPUTRated power 6000 VAVoltage 220-230-240 VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OU
Riello Sentinel Pro UPS SEP 700
Riello Sentinel Pro UPS SEP 700
Specifications:INPUTRated power 700 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Vision Dual UPS VSD 3000 ER
Riello Vision Dual UPS VSD 3000 ER
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacFrequency 50/60 Hz with automatic selectionFrequency tolerance ± 5HzPower factor > 0,98Current distorsion < 7%OUTPUT and INVERTER OUTPUTRated power 3000 VAActive power 2400 WNumber phases 1Crest factor (Ipeak/Irms) 2,5:1Wave form on batt
Riello Master MPS UPS MPT 20
Riello Master MPS UPS MPT 20
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated fre
Riello iPlug UPS IPG 600
Riello iPlug UPS IPG 600
Specifications:INPUTRated power 600 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz with auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (+/- 1%)
Riello Master MPS UPS MPM 60
Riello Master MPS UPS MPM 60
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 360-400-420 Vac three-phase + NRated frequen