Specifications:
INPUT
Voltage 220-240 Vac
Voltage tolerance 230 Vac (+ 20 / - 26%)
Frequency 50/60 Hz auto sensing
OUTPUT and INVERTER OUTPUT
Rated power 800 VA
Active power 480 W
Wave form on battery Pseudo sinewave
Frequency on battery operation 50 or 60 Hz (± 0.5%)
BATTERIES
Type Maintenance-free sealed lead-acid
Typical recharge time 2÷4 h

Riello Multi Guard UPS GMT 120
Riello Multi Guard UPS GMT 120
Specifications:INPUTFrequency tolerance between 40 Hz and 70 HzPower factor >0.99BY PASSRated voltage 380-400-415 Vac, three-phase + NOUTPUT and INVERTER OUTPUTRated power 15 kVA / 13.5 kW per module VAFrequency 50 Hz / 60 HzENVIRONMENTALSafety compliance IEC 62040-1Noise from ≤ 60 dBA to ≤ 62 d
Riello Sentinel Dual (Low Power) UPS SDH 2200
Riello Sentinel Dual (Low Power) UPS SDH 2200
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency
Riello Multi Sentry UPS MST 60
Riello Multi Sentry UPS MST 60
Specifications:INPUTRated power 60000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Multi Sentry UPS MST 10
Riello Multi Sentry UPS MST 10
Specifications:INPUTRated power 10000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Pro UPS SEP 2200
Riello Sentinel Pro UPS SEP 2200
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Master MPS UPS MPT 10
Riello Master MPS UPS MPT 10
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated fre
Riello Sentinel Power UPS SPT 10000
Riello Sentinel Power UPS SPT 10000
Specifications:INPUTRated power 10000 VAVoltage 220-230-240 Vac single-phase or 380-400-415 Vac three-phase with neutral VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Freq
Riello Master HE UPS MHE 120
Riello Master HE UPS MHE 120
Specifications: INPUT Rated power 120000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 169 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Sentinel Power Green UPS SPH 10
Riello Sentinel Power Green UPS SPH 10
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 10000 VAActive power 9000 WWaveform SinusoidalOVERLOAD TIME
Riello Multi Sentry UPS MST 80
Riello Multi Sentry UPS MST 80
Specifications:INPUTINPUTRated power 80000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ±