Specifications:
INPUT
Voltage 220-230-240 Vac
Frequency 50/60 Hz +/- 10 Hz
BY PASS
Voltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)
Frequency tolerance Selected frequency ±10%
OUTPUT and INVERTER OUTPUT
Rated power 10000 VA
Active power 9000 W
Waveform Sinusoidal
OVERLOAD TIMES
100% < Load < 110% 5 min
100% < Load < 120% 1 min
125% = Load < 150% 10 sec
Load = 150% 0,1 sec
BATTERIES
Type VRLA AGM maintenance-free lead based
Typical recharge time 6-8 hours

Riello Master HE UPS MHE 400
Riello Master HE UPS MHE 400
Specifications: INPUT Rated power 400000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 564 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Sentinel Dual (Low Power) UPS SDH 3000 ER
Riello Sentinel Dual (Low Power) UPS SDH 3000 ER
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency
Riello Multi Sentry UPS MST 40
Riello Multi Sentry UPS MST 40
Specifications:INPUTRated power 40000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Master Industrial UPS MIM 80
Riello Master Industrial UPS MIM 80
Specifications: INPUT Rated power 80000 VA Voltage 400 Vac three-phase Vac Voltage tolerance ± 20% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0.93 Current distorsion <5% Soft start 0-100% in 10" BY PASS Rated voltage 400 Vac three-phase selectable 380
Riello Sentinel Power UPS SPT 8000
Riello Sentinel Power UPS SPT 8000
Specifications:INPUTRated power 8000 VAVoltage 220-230-240 Vac single-phase or 380-400-415 Vac three-phase with neutral VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequ
Riello Master HE UPS MHE 300
Riello Master HE UPS MHE 300
Specifications: INPUT Rated power 300000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 423 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Vision Dual UPS VSD 1100
Riello Vision Dual UPS VSD 1100
Specifications: INPUT Rated power 1100 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 1100 VA Active power 990 W Number phases 1 Crest factor (Ipeak
Riello Master MPS UPS MPT 30
Riello Master MPS UPS MPT 30
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph
Riello Master HP UPS MHT 500
Riello Master HP UPS MHT 500
SpecificationsINPUTRated power 500000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 702 ACurrent distorsion
Riello Master MPS UPS MPM 60
Riello Master MPS UPS MPM 60
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 360-400-420 Vac three-phase + NRated frequen