SMA Central Inverters SUNNY CENTRAL 1600MV-20

SMA Central Inverters SUNNY CENTRAL 1600MV-20
share

For even more power per surface area: up to two high-performance Sunny Central HE-20 are part of a medium-voltage station (MV) that feeds directly into a shared medium-voltage transformer. This transforms two Sunny Central 800HE inverters, for example, into one Sunny Central 1600MV station. A peak efficiency of more than 98 percent is achieved using an amorphous transformer. The new MV station integrates highperformance communications components and also requires even less maintenance. Moreover, the new MV station offers extensive grid management functions and fulfills all of the requirements of the medium-voltage directive.
Powerful
Peak output of up to 1,760 kVA
Turnkey solution for direct connection to the medium-voltage grid
High yields plus reliability
Max. yields thanks to an optimized AC power path
Comprehensive grid management functions including complete dynamic grid support (BDEW compliant)
Communicative
High-performance industrial PC with a range of integrated interfaces
Open communication interfaces, for example, Modbus, OPC
Flexible
Medium-voltage switchgear systems for flexibly designing large PV farms
Amorphous transformer for minimal open-circuit losses
Use in a chemically aggressive environment
Input (DC)
Max. DC power (@ cos Ï† = 1) 1796 kW
Max. input voltage 1) 1000 V / 1100 V optional
MPP voltage range (@ 25°C / @ 40°C at 50 Hz) 2) 641 V â€“ 820 V / 583 V â€“ 820 V
Rated input voltage 620 V
Max. input current 2800 A
Min. input voltage / VMPP_min at IMPP < IDCmax 568 V / 570 V
Number of independent MPP inputs 2
Number of DC inputs 18 inputs equipped with fuses
-Output (AC)
Rated power (@ 25 °C) / nominal AC power (@ 40 °C) 1760 kVA / 1600 kVA
Nominal AC voltage / range 20000 V / 18000 V â€“ 22000 V
AC power frequency / range 50 Hz / 47 Hz ... 53 Hz
Rated power frequency / rated grid voltage 50 Hz / 20000 V
Max. output current 50.8 A
Max. total harmonic factor < 3 %
Power factor at rated power / displacement power factor adjustable 3) 1 / 0.9 overexcited ... 0.9 underexcited
Feed-in phases / connection phases 3 / 3
-Efficiency 4)
Max. efficiency 98 % (98.2 %) 5)
European weighted efficiency / CEC efficiency 97.6 % (97.8 %)5)
-Protective devices
DC disconnect device Motor-driven DC switch-disconnector
AC disconnect device Optionally (switch-disconnector with HH fuses)
DC overvoltage protection / AC overvoltage protection on the LV side Surge arrester type I / surge arrester type II
Grid monitoring / plant monitoring yes / Optionally (via Sunny Portal)
Ground-fault monitoring / remote-controlled ground-fault monitoring opt. / opt.
Insulation monitoring opt.
Galvanic isolation yes
Protection class (according to IEC 62103)3) / electric arc resistance (according to IEC 62271-202) I / IAC AB 20 kA 1s
-General data
Dimensions (W / H / D) 5800 / 3605 / 3000 mm(228.3 / 141.9 / 118.1 inch)
Weight 37185 kg / 81979 lb
Operating temperature range -20 °C ... +40 °C /-4 °F ... +104 °F
Noise emission < 65 dB(A)
Max. self-consumption (operation) / self-consumption (night) 3000 W 3) / < 180 W + 1700 W5)
External auxiliary supply voltage / external back-up fuse for auxiliary power supply 230 / 400 V (3 / N / PE) / B 32 A, 3-pin
Cooling principle (inverter / transformer) Forced cooling / natural convection
Degree of protection (according to IEC 60529) 7) IP23D
Application In unprotected outdoor environments
Use in a chemically aggressive environment opt.
Max. permissible value for relative humidity (non-condensing) 15 % ... 95 %
Max. operating altitude above MSL 1000 m
Fresh-air consumption (inverter) 6000 m³/h
-Features
DC connection Ring terminal lug
AC connection, MV side External taper angle plug
Display 3) HMI touchscreen
Communication protocols / Sunny String-Monitor Ethernet, Modbus / RS485 / none (Optiprotect)
SC-COM/Communit yes / opt.
Transformer for auxiliary power supply opt.
Medium-voltage transformer with amorphous core opt.
Medium-voltage switchgear opt.
Color enclosure / door / base / roof RAL 7035 / 7024 / 7024 / 7024
Certificates and approvals (more available on request) EN 61000-6-2, EN 61000-6-4, IEC 62271-202, EMC compliant, CE compliant, BDEW-MSRL / FGW / TR86), Arrêté du 23/04/08, R.D. 1663 / 2000, R.D. 661 / 2007

SMA Battery Inverters SUNNY ISLAND 5048 Multicluster-Box 36
SMA Battery Inverters SUNNY ISLAND 5048 Multicluster-Box 36
The Multicluster Boxes for Sunny Island 5048 allow the formation of off-grid and hybrid systems with a capacity of between 20 and 300 kW. As the main AC distrib
SMA Central Inverters SUNNY CENTRAL 1600MV-20
SMA Central Inverters SUNNY CENTRAL 1600MV-20
For even more power per surface area: up to two high-performance Sunny Central HE-20 are part of a medium-voltage station (MV) that feeds directly into a shared medi
SMA Battery Inverters Sunny Island Charger 24 V
SMA Battery Inverters Sunny Island Charger 24 V
AC and DC coupling in perfect interaction and from a single manufacturer: the all-purpose Sunny Island Charger 50 by SMA. Its broad DC input voltage range makes conf
SMA Wind Energy Inverters WINDY BOY 2500
SMA Wind Energy Inverters WINDY BOY 2500
Windy Boy 2500 and 3000 inverters are ideally suited to small wind turbine systems, and feature a maximum efficiency of 95 percent. The programmable polynomial curve enab
SMA Wind Energy Inverters WINDY BOY 3600TL
SMA Wind Energy Inverters WINDY BOY 3600TL
With even better communication, usability and efficiency, the Windy Boy 3600TL and 5000 TL inverters set new standards. With a modern graphic display, a simplified mounting&nb
SMA Battery Inverters SUNNY REMOTE CONTROL
SMA Battery Inverters SUNNY REMOTE CONTROL
Systems using Sunny Island and Sunny Backup are now even more fl exible: to maximize the user convenience, we have moved the control unit on the outside of the&
SMA Wind Energy Inverters WINDY BOY 1200
SMA Wind Energy Inverters WINDY BOY 1200
Ideal for small wind turbine systems: The programmable polynomial curve of the Windy Boy 1200 and 1700 inverters allows optimal adjustment to the turbine characteristic curve&
SMA Central Inverters SUNNY CENTRAL 1000MV-20
SMA Central Inverters SUNNY CENTRAL 1000MV-20
For even more power per surface area: up to two high-performance Sunny Central HE-20 are part of a medium-voltage station (MV) that feeds directly into a shared medi
SMA Central Inverters TRANSFORMER COMPACT STATION 900SC
SMA Central Inverters TRANSFORMER COMPACT STATION 900SC
The Transformer Compact Station â€“ now also for 900 kVA nominal power â€“ is the ideal link between SMA central inverters and the medium-voltage grid. As a&nbs
SMA Wind Energy Inverters WINDY BOY 5000TL
SMA Wind Energy Inverters WINDY BOY 5000TL
With even better communication, usability and efficiency, the Windy Boy 3600TL and 5000 TL inverters set new standards. With a modern graphic display, a simplified mounting&nb