Universally applicable: the Sunny Boy inverters 1200, 1700, 2500 and 3000 are used in the most diverse AC grids thanks to their galvanic isolation. In addition, the devices are suitable for simple grounding of the PV array. Their integrated ESS DC switch-disconnector makes installation simpler while also reducing installation costs. Equipped with the OptiTrac MPP-tracking process, it will always find the best working point, even under dynamic weather conditions, and reliably converts solar energy into solar yield.
Reliable
Integrated ESS DC switch-disconnector
Galvanic isolation
Versatile
For indoor and outdoor installation
Suitable for PV array grounding
Reliable
Proven technology
Maintenance free, thanks to convection cooling
Simple
SUNCLIX DC plug-in system
-Input (DC)
Max. DC power (@ cos Ï†=1) 2700 W
Max. input voltage 600 V
MPP voltage range / rated input voltage 224 V â€“ 480 V / 300 V
Min. input voltage / initial input voltage 224 V / 300 V
Max. input current 12 A
Max. input current per string 12 A
Number of independent MPP inputs / strings per MPP input 1 / 3
-Output (AC)
Rated output power (@ 230 V, 50 Hz) 2300 W
Max. apparent AC power 2500 VA
Nominal AC voltage / range 220 V, 230 V, 240 V / 180 V â€“ 265 V
AC power frequency / range 50 Hz, 60 Hz / -4.5 Hz ... +4.5 Hz
Rated power frequency / rated power voltage 50 Hz / 230 V
Max. output current 12.5 A
Power factor at rated power 1
Adjustable displacement factor —
Feed-in phases / connection phases 1 / 1
-Efficiency
Max. efficiency / European efficiency 94.1 % / 93.2 %
-Protective devices
Input-side disconnection device yes
Ground-fault monitoring / grid monitoring yes / yes
DC surge arrester Type II, can be integrated —
DC reverse-polarity protection / AC short-circuit current capability / galvanically isolated yes / yes / yes
All-pole sensitive residual current monitoring unit —
Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) I / III
-General data
Dimensions (W / H / D) 440 / 339 / 214 mm(17.3 / 13.3 / 8.4 inch)
Weight 28 kg / 61.7 lb
Operating temperature range -25 °C ... +60 °C / -13 °F ... +140 °F
Noise emission (typical) 33 dB(A)
Internal consumption (night) 0.25 W
Topology LF transformer
Cooling concept Convection
Degree of protection (according to IEC 60529) IP65
Degree of protection of connection area (according to IEC 60529) IP65
Climatic category (according to IEC 60721-3-4) 4K4H
Maximum permissible value for relative humidity (non-condensing) 100 %
-Features
DC terminal SUNCLIX
AC terminal Connector
Display Text line
Interface: RS485 / Bluetooth opt. / opt.
Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt.
Multi-function relay —
Certificates and approvals (more available on request) CE, VDE0126-1-1, G83/1-1, CER/06/190, RD 1663/2000, RD 661/2007, PPC, AS4777, EN 50438*, PPDS, DK 5940 ED2.2**, C10/11

SAM Solar Inverters without Transformer SUNNY BOY 2500TL-21 SINGLE TRACKER
SAM Solar Inverters without Transformer SUNNY BOY 2500TL-21 SINGLE TRACKER
Electrifying detail: Thanks to the higher, 750 volt maximum DC input voltage, often times one less module string is needed because more modules can be switched on in
SMA Solar Inverters with Transformer SUNNY BOY 7000-US
SMA Solar Inverters with Transformer SUNNY BOY 7000-US
Maximum energy yields for a continuously expanding photovoltaic market: the Sunny Boys with UL listing is impressive with its excellent efficiency. Graduated power classes provide&
SMA Solar Inverters with Transformer SUNNY BOY 2500HF
SMA Solar Inverters with Transformer SUNNY BOY 2500HF
The Sunny Boy HF offers a nearly unlimited range of options for the planning phase. A wide input voltage range of 175-700 volts means that most configurations can&nb
SMA Solar Inverters with Transformer SUNNY BOY 3300
SMA Solar Inverters with Transformer SUNNY BOY 3300
It is robust, easy-to-handle, and, thanks to its galvanic isolation, can be used in all kinds of AC grids: the Sunny Boy 3300 / 3800. Due to its suitability&nbs
SAM Solar Inverters without Transformer SUNNY BOY 8000TL-US
SAM Solar Inverters without Transformer SUNNY BOY 8000TL-US
With peak efficiencies of 98.3%, the transformerless Sunny Boy TL-US provide their owners with high yields. The power classes, finely tiered from 6 kW to 11kW, are i
SMA Solar Inverters with Transformer SUNNY BOY 3000HF-US
SMA Solar Inverters with Transformer SUNNY BOY 3000HF-US
This is the new generation of inverters designed for the countries with UL listing â€“ packed full of the latest SMA technology, these devices provide the highest&nb
SAM Solar Inverters without Transformer SUNNY BOY 3000TL-21 SINGLE TRACKER
SAM Solar Inverters without Transformer SUNNY BOY 3000TL-21 SINGLE TRACKER
Electrifying detail: Thanks to the higher, 750 volt maximum DC input voltage, often times one less module string is needed because more modules can be switched on in
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 10000TL
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 10000TL
At home with leading-edge technology and top yields: The Sunny Tripower PV plant with 5 to 9 kW of power is setting new standards for home systems. It features&
SAM Solar Inverters without Transformer SUNNY BOY 4000TL RPC
SAM Solar Inverters without Transformer SUNNY BOY 4000TL RPC
Electrifying detail: Thanks to the higher, 750 volt maximum DC input voltage, often times one less module string is needed because more modules can be switched on in
SMA Solar Inverters with Transformer SUNNY BOY 2000HF
SMA Solar Inverters with Transformer SUNNY BOY 2000HF
The Sunny Boy HF offers a nearly unlimited range of options for the planning phase. A wide input voltage range of 175-700 volts means that most configurations can&nb