- power supply
- TDK Lambda Power Supply
- Yamaha Power Supply
- Omron Power Supply
- Plus Power Supply
- Bestec Power Supply
- Sorensen Power Supply
- Antec Power Supply
- Meanwell Power Supply
- Weidmuller Power Supply
- Hipro Power Supply
- Sparkle Power Supply
- Lenovo Power Supply
- Zippy Power Supply
- Enermax Power Supply
- Agilent Power Supply
- Phihong Power Supply
- Liteon power supply
- Acble Power Supply
- Instek Power Supply
- Zalman Power Supply
- FSP Power Supply
- Aopen Power Supply
- Spellman Supply
- Delta Supply
- Cosel Supply
- Aj`s Power Source Supply
- Coolmax Supply
- MEAN WELL Power Supply
- SENDON Power Supply
- MGE Power Supply
- UPS Power Supply
- APC UPS Power Supply
- Riello UPS Power Supply
- EATON UPS Power Supply
- SANTAK UPS Power Supply
- Siemens UPS Power Supply
- Powerware UPS Power Supply
- OMRON UPS Power Supply
- Mitsubishi UPS Power Suppply
- DELTA Uninterruptible Power Supply
- EAST UPS Power Supply
- EMERSON UPS Power Supply
- Fuji UPS Power Supply
- EFFEKTA Uninterruptible Power Supply
- Gutor UPS Power Supply
- KELONG UPS Power Supply
- LADIS Uninterruptible Power Supply
- CBC UPS Power Supply
- Phoenix UPS Power Supply
- SVC Uninterruptible Power Supply
- Avaya UPS Power Supply
- NETCCA Uninterruptible Power Supply
- battery
- inverter
- Xantrex inverter
- Samlex inverter
- Schumacher inverter
- KACO inverter
- Wagan inverter
- AIMS inverter
- Victron inverter
- Targus inverter
- Whistler inverter
- Enphase inverter
- Satcon inverter
- Sima inverter
- Kensington inverter
- Exeltech inverter
- Stanley inverter
- ABB inverter
- SMA inverter
- Hyundai inverter
- Mastervolt inverter
- YAMAHA inverter
- Belkin inverter
- Microtek inverter
- Growatt inverter
- TDK inverter
- TOSHIBA inverter
- Su kam inverter
- Omnik inverter
- Ingeteam inverter
- Samil Power inverter
- Sungrow inverter
- Cobra inverter
- Power Bright inverter
- Bestek inverter
- A&S Power Supply Co.,Ltd
- Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
- Tel:+86-28-65376776
- Fax:+86-28-86129221
- Email:inverter@electrical8.com
- Contact Person:Karina
SMA Solar Inverters with Transformer SUNNY BOY 8000-US
Maximum energy yields for a continuously expanding photovoltaic market: the Sunny Boys with UL listing is impressive with its excellent efficiency. Graduated power classes provide flexibility in plant planning. The automatic grid voltage detection¹ allows easy and safe installation. Furthermore, the galvanic isolation provides flexible connection possibilities. The Sunny Boy inverters can be used with crystalline cells as well as thin-film PV modules.
UL listed
For countries that require UL listing (UL 1741 / IEEE 1547 / CAN CSA C22.2 107)
Economical
97 % peak efficiency
OptiCool active temperature management
Reliable
Galvanic isolation
Arc-fault circuit interrupter, optional (AFCI)
Simple
Automatic grid voltage detection¹
Integrated DC switch-disconnector
¹ US patent US7352549B1
240 V277 V
-Input (DC)
Max. recommended PV power (@ module STC) 10000 W
Max. DC power (@ cos φ = 1) 8600 W
Max. input voltage 600 V
MPP voltage range / rated input voltage 300 V – 480 V / 345 V
Min. input voltage / initial input voltage 300 V / 365 V
Max. input current 30 A
Max. string fuse on the DC disconnector 20 A
Number of independent MPP inputs 1
Strings per MPP input (@ DC disconnector) 4
-Output (AC)
Rated power / max. apparent AC power 7680 W / 8000 VA
Nominal AC voltage / nominal AC voltage range 240 V / 211 V – 264 V277 V / 244 V – 305 V
AC power frequency / range 60 Hz / 59.3 Hz ... 60.5 Hz
Max. output current 34 A29 A
Power factor at rated power 1
Feed-in phases / connection phases 1 / 21 / 1
-Efficiency
CEC efficiency / max. efficiency 96 % / 96.3 %96 % / 96.5 %
-Protective devices
DC reverse polarity protection yes
AC short-circuit current capability yes
Galvanically isolated yes
Arc-fault circuit interrupter (in accordance with UL1699B)² opt.
Protection class (according to IEC 62103) I
Overvoltage category (according to IEC 60664-1) III
-General data
Dimensions (W / H / D) 470 / 615 / 240 mm(18.4 / 24.1 / 9.5 inch)
Dimensions of DC Disconnect (W / H / D) 187 / 297 / 190 mm(7.3 / 11.7 / 7.5 inch)
Weight 66 kg / 145 lb
Weight of DC Disconnect 3.5 kg / 8 lb
Operating temperature range² -25 °C ... +45 °C /-13 °F ... +113 °F
Noise emission (typical) 49 dB(A)
Self-consumption (night) 0.1 W
Topology LF transformer
Cooling concept OptiCool
Degree of protection NEMA 3R
Degree of protection of connection area NEMA 3R
Max. permissible value for relative humidity (non-condensing) 100 %
-Features
DC connection Screw terminal
AC connection Screw terminal
Display Text line
Interface: RS485 / Bluetooth opt. / opt.
Warranty: 10 / 15 / 20 years yes / opt. / opt.
Certifi cates and approvals (more available on request) UL1741, UL1998, IEEE1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1, C22.2, UL 1699B
More modules can be connected in series with the Sunny Mini Central 7000HV than with common inverters. This reduces cabling costs on the DC side and simplifies the&n
At home with leading-edge technology and top yields: The Sunny Tripower PV plant with 5 to 9 kW of power is setting new standards for home systems. It features&
With peak efficiencies of 98.3%, the transformerless Sunny Boy TL-US provide their owners with high yields. The power classes, finely tiered from 6 kW to 11kW, are i
At home with leading-edge technology and top yields: The Sunny Tripower PV plant with 5 to 9 kW of power is setting new standards for home systems. It features&
With peak efficiencies of 98.3%, the transformerless Sunny Boy TL-US provide their owners with high yields. The power classes, finely tiered from 6 kW to 11kW, are i
Optiflex is the first of our new features.Its outstanding flexibility opens up endless possibilities.How? Through an asymmetrically dimensioned multistring input combined with a broad&n
Electrifying detail: Thanks to the higher, 750 volt maximum DC input voltage, often times one less module string is needed because more modules can be switched on in
The Sunny Mini Central 4600A, 5000A and 6000A are installed wherever galvanic isolation is required. This means they can be universally used for many different types of&n
Specially designed for countries that require UL listing, these Sunny Boy inverters guarantee a safe installation process thanks to the automatic grid voltage detection¹. The 
Optiflex is the first of our new features.Its outstanding flexibility opens up endless possibilities.How? Through an asymmetrically dimensioned multistring input combined with a broad&n