SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 9000TLRP

SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 9000TLRP
share

Sunny Mini Central inverters with Reactive Power Control are the ideal solution when utility companies demand reactive power supply. They can be used to realize plant designs which specify for the displacement factor cos Ï† and the corresponding percentage of reactive power. Large PV power stations can now make optimum use of grid distribution capacities, which significantly contributes to the success of renewable energy.
Flexible
Reactive power supply
High yields
Maximum efficiency of 97.7 %
Transformerless, with H5 topology
OptiCool active temperature management
Reliable
Pluggable SMA Power Balancer for three-phase grid connection
Integrated ESS DC switchdisconnector
Monitored string fuses
Simple
SUNCLIX DC plug-in system
-Input (DC)
Max. DC power (@ cos Ï† = 1) 9300 W
Max. input voltage 700 V
MPP voltage range / rated input voltage 333 V â€“ 500 V / 350 V
Min. input voltage / initial input voltage 333 V / 400 V
Max. input current 28 A
Max. input current per string 28 A
Number of independent MPP inputs / strings per MPP input 1 / 5


Output (AC)
Rated power (@ 230 V, 50 Hz) 9000 W
Max. apparent AC power 9000 VA
Nominal AC voltage / range 220 V, 230 V, 240 V / 180 V â€“ 265 V
AC power frequency / range 50 Hz, 60 Hz / -6 Hz ... +5 Hz
Rated power frequency / rated grid voltage 50 Hz / 230 V
Max. output current 40 A
Power factor at rated power 1
Adjustable displacement power factor 0.8 overexcited ... 0.8 underexcited
Feed-in phases / connection phases 1 / 1
Power balancing yes

-Efficiency
Max. efficiency / European weighted efficiency 97.7 % / 97.3 %
Protective devices
Reverse current protection / DC disconnect device Optional (fuses) / yes
Ground fault monitoring / grid monitoring yes / yes
DC reverse polarity protection / AC short-circuit current capability / galvanically isolated yes / yes / â€”
All-pole-sensitive residual-current monitoring unit yes
Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) I / III

General data
Dimensions (W / H / D) 468 / 613 / 242 mm(18.4 / 24.1 / 9.5 inch)
Weight 35 kg / 77.16 lb
Operating temperature range -25 °C ... +60 °C /-13 °F ... +140 °F
Noise emission (typical) 42 dB(A)
Self-consumption (night) 0.25 W
Topology Transformerless
Cooling concept OptiCool
Degree of protection (according to IEC 60529) IP65
Degree of protection of connection area (according to IEC 60529) IP65
Climatic category (according to IEC 60721-3-4) 4K4H
Max. permissible value for relative humidity (non-condensing) 100 %

-Features
DC coupling SUNCLIX
AC coupling Screw terminal
Display Text line
Interface: RS485 / Bluetooth opt. / opt.
Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt.
Certificates and approvals (more available on request) CE, VDE0126-1-1, AR4105, EN50438¹, C10/11, PPDS, IEC61727, UTEC15-712-1, RD1699, RD 661/2007

SMA Solar Inverters with Transformer SUNNY BOY 8000-US
SMA Solar Inverters with Transformer SUNNY BOY 8000-US
Maximum energy yields for a continuously expanding photovoltaic market: the Sunny Boys with UL listing is impressive with its excellent efficiency. Graduated power classes provide&
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 10000TLRP
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 10000TLRP
Sunny Mini Central inverters with Reactive Power Control are the ideal solution when utility companies demand reactive power supply. They can be used to realize plant des
SMA Solar Inverters with Transformer SUNNY BOY 3300
SMA Solar Inverters with Transformer SUNNY BOY 3300
It is robust, easy-to-handle, and, thanks to its galvanic isolation, can be used in all kinds of AC grids: the Sunny Boy 3300 / 3800. Due to its suitability&nbs
SMA Solar Inverters with Transformer SUNNY BOY 1200
SMA Solar Inverters with Transformer SUNNY BOY 1200
Universally applicable: the Sunny Boy inverters 1200, 1700, 2500 and 3000 are used in the most diverse AC grids thanks to their galvanic isolation. In addition, the 
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 8000TL
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 8000TL
The transformerless SMA Sunny Mini Central 6000TL, 7000TL and 8000TL PV inverters provide their owners with high yields. With the Sunny Mini Central family of transformerless&
SAM Solar Inverters without Transformer SUNNY BOY 5000TL RPC
SAM Solar Inverters without Transformer SUNNY BOY 5000TL RPC
Electrifying detail: Thanks to the higher, 750 volt maximum DC input voltage, often times one less module string is needed because more modules can be switched on in
SMA Solar Inverters with Transformer SUNNY BOY 5000-US
SMA Solar Inverters with Transformer SUNNY BOY 5000-US
Maximum energy yields for a continuously expanding photovoltaic market: the Sunny Boys with UL listing is impressive with its excellent efficiency. Graduated power classes provide&
SMA Solar Inverters with Transformer SUNNY BOY 6000-US
SMA Solar Inverters with Transformer SUNNY BOY 6000-US
Maximum energy yields for a continuously expanding photovoltaic market: the Sunny Boys with UL listing is impressive with its excellent efficiency. Graduated power classes provide&
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 7000TL
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 7000TL
The transformerless SMA Sunny Mini Central 6000TL, 7000TL and 8000TL PV inverters provide their owners with high yields. With the Sunny Mini Central family of transformerless&
SMA Solar Inverters with Transformer SUNNY BOY 2000HF
SMA Solar Inverters with Transformer SUNNY BOY 2000HF
The Sunny Boy HF offers a nearly unlimited range of options for the planning phase. A wide input voltage range of 175-700 volts means that most configurations can&nb