SMA Solar Inverters with Transformer SUNNY BOY 3300

SMA Solar Inverters with Transformer SUNNY BOY 3300
share

It is robust, easy-to-handle, and, thanks to its galvanic isolation, can be used in all kinds of AC grids: the Sunny Boy 3300 / 3800. Due to its suitability for PV array grounding, it can be combined with all module types. The die-cast aluminum enclosure, with the OptiCool active cooling system guarantees the highest yields and a long service life, even under extreme conditions.
Powerful
Efficiency of up to 95.6 %
OptiCool active temperature management
OptiTrac MPP tracking for best tracking efficiency
Reliable
Galvanic isolation
Integrated ESS DC switch-disconnector
Flexible
For indoor and outdoor installation
Suitable for PV array grounding
Simple
SUNCLIX DC plug-in system
-Input (DC)
Max. DC power (@ cos Ï†=1) 3820 W
Max. input voltage 500 V
MPP voltage range / rated input voltage 200 V â€“ 400 V / 200 V
Min. input voltage / initial input voltage 200 V / 250 V
Max. input current 20 A
Max. input current per string 16 A
Number of independent MPP inputs / strings per MPP input 1 / 3
-Output (AC)
Rated output power (@ 230 V, 50 Hz) 3300 W
Max. apparent AC power 3600 VA
Nominal AC voltage / range 220 V, 230 V, 240 V / 180 V â€“ 265 V
AC power frequency / range 50 Hz, 60 Hz / -4.5 Hz ... +4.5 Hz
Rated power frequency / rated power voltage 50 Hz / 230 V
Max. output current 18 A
Power factor at rated power 1
Adjustable displacement factor —
Feed-in phases / connection phases 1 / 1
-Efficiency
Max. efficiency / European efficiency 95.2 % / 94.4 %
-Protective devices
Input-side disconnection device yes
Ground-fault monitoring / grid monitoring yes / yes
DC surge arrester Type II, can be integrated —
DC reverse-polarity protection / AC short-circuit current capability / galvanically isolated yes / yes / yes
All-pole sensitive residual current monitoring unit —
Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) I / III
-General data
Dimensions (W / H / D) 450 / 352 / 236 mm(17.7 / 13.9 / 9.3 inch)
Weight 38 kg / 83.6 lb
Operating temperature range -25 °C ... +60 °C / -13 °F ... +140 °F
Noise emission (typical) 40 dB(A)
Internal consumption (night) 0.1 W
Topology LF transformer
Cooling concept OptiCool
Degree of protection (according to IEC 60529) IP65
Degree of protection of connection area (according to IEC 60529) IP65
Climatic category (according to IEC 60721-3-4) 4K4H
Maximum permissible value for relative humidity (non-condensing) 100 %
-Features
DC terminal SUNCLIX
AC terminal Connector
Display Text line
Interface: RS485 / Bluetooth opt. / opt.
Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt.
Multi-function relay —
Certificates and approvals (more available on request) CE, VDE0126-1-1, DK 5940 ED2.2**, G83/1-1, CER/06/190, RD 1663/2000, RD 661/2007, PPC, AS4777, EN 50438*, PPDS, UTE C15-712-1, C10/11

SAM Solar Inverters without Transformer SUNNY TRIPOWER 5000TL-20
SAM Solar Inverters without Transformer SUNNY TRIPOWER 5000TL-20
At home with leading-edge technology and top yields: The Sunny Tripower PV plant with 5 to 9 kW of power is setting new standards for home systems. It features&
SAM Solar Inverters without Transformer SUNNY BOY 2100TL
SAM Solar Inverters without Transformer SUNNY BOY 2100TL
Combining a broad input voltage range and a broad input current range, the transformerless Sunny Boy can be connected to nearly all standard crystalline PV modules. As&nb
SMA Solar Inverters with Transformer SUNNY BOY 3300
SMA Solar Inverters with Transformer SUNNY BOY 3300
It is robust, easy-to-handle, and, thanks to its galvanic isolation, can be used in all kinds of AC grids: the Sunny Boy 3300 / 3800. Due to its suitability&nbs
SAM Solar Inverters without Transformer SUNNY TRIPOWER 20000TL-10 Economic Excellence
SAM Solar Inverters without Transformer SUNNY TRIPOWER 20000TL-10 Economic Excellence
Peak performance and technological perfection at a significantly reduced specific price: the new Sunny Tripower TL Economic Excellence is the next logical step in the developm
SAM Solar Inverters without Transformer SUNNY BOY 5000TL RPC
SAM Solar Inverters without Transformer SUNNY BOY 5000TL RPC
Electrifying detail: Thanks to the higher, 750 volt maximum DC input voltage, often times one less module string is needed because more modules can be switched on in
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 10000TLRP
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 10000TLRP
Sunny Mini Central inverters with Reactive Power Control are the ideal solution when utility companies demand reactive power supply. They can be used to realize plant des
SMA Solar Inverters with Transformer SUNNY BOY 2500HF
SMA Solar Inverters with Transformer SUNNY BOY 2500HF
The Sunny Boy HF offers a nearly unlimited range of options for the planning phase. A wide input voltage range of 175-700 volts means that most configurations can&nb
SMA Solar Inverters with Transformer SUNNY BOY 3800-US
SMA Solar Inverters with Transformer SUNNY BOY 3800-US
Specially designed for countries that require UL listing, these Sunny Boy inverters guarantee a safe installation process thanks to the automatic grid voltage detection¹. The 
SMA Solar Inverters with Transformer SUNNY BOY 4000-US
SMA Solar Inverters with Transformer SUNNY BOY 4000-US
Specially designed for countries that require UL listing, these Sunny Boy inverters guarantee a safe installation process thanks to the automatic grid voltage detection¹. The 
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 9000TLRP
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 9000TLRP
Sunny Mini Central inverters with Reactive Power Control are the ideal solution when utility companies demand reactive power supply. They can be used to realize plant des