- power supply
- TDK Lambda Power Supply
- Yamaha Power Supply
- Omron Power Supply
- Plus Power Supply
- Bestec Power Supply
- Sorensen Power Supply
- Antec Power Supply
- Meanwell Power Supply
- Weidmuller Power Supply
- Hipro Power Supply
- Sparkle Power Supply
- Lenovo Power Supply
- Zippy Power Supply
- Enermax Power Supply
- Agilent Power Supply
- Phihong Power Supply
- Liteon power supply
- Acble Power Supply
- Instek Power Supply
- Zalman Power Supply
- FSP Power Supply
- Aopen Power Supply
- Spellman Supply
- Delta Supply
- Cosel Supply
- Aj`s Power Source Supply
- Coolmax Supply
- MEAN WELL Power Supply
- SENDON Power Supply
- MGE Power Supply
- UPS Power Supply
- APC UPS Power Supply
- Riello UPS Power Supply
- EATON UPS Power Supply
- SANTAK UPS Power Supply
- Siemens UPS Power Supply
- Powerware UPS Power Supply
- OMRON UPS Power Supply
- Mitsubishi UPS Power Suppply
- DELTA Uninterruptible Power Supply
- EAST UPS Power Supply
- EMERSON UPS Power Supply
- Fuji UPS Power Supply
- EFFEKTA Uninterruptible Power Supply
- Gutor UPS Power Supply
- KELONG UPS Power Supply
- LADIS Uninterruptible Power Supply
- CBC UPS Power Supply
- Phoenix UPS Power Supply
- SVC Uninterruptible Power Supply
- Avaya UPS Power Supply
- NETCCA Uninterruptible Power Supply
- battery
- inverter
- Xantrex inverter
- Samlex inverter
- Schumacher inverter
- KACO inverter
- Wagan inverter
- AIMS inverter
- Victron inverter
- Targus inverter
- Whistler inverter
- Enphase inverter
- Satcon inverter
- Sima inverter
- Kensington inverter
- Exeltech inverter
- Stanley inverter
- ABB inverter
- SMA inverter
- Hyundai inverter
- Mastervolt inverter
- YAMAHA inverter
- Belkin inverter
- Microtek inverter
- Growatt inverter
- TDK inverter
- TOSHIBA inverter
- Su kam inverter
- Omnik inverter
- Ingeteam inverter
- Samil Power inverter
- Sungrow inverter
- Cobra inverter
- Power Bright inverter
- Bestek inverter
- A&S Power Supply Co.,Ltd
- Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
- Tel:+86-28-65376776
- Fax:+86-28-86129221
- Email:inverter@electrical8.com
- Contact Person:Karina
SMA Wind Energy Inverters WINDY BOY 3000-US
User-friendly, safe and reliable: the Windy Boys in the 3000, 3800 and 4000 watt power classes are specially certified for the US market. The automatic grid voltage detection¹ allows for a straightforward and secure installation. The programmable polynomial curve offers the greatest freedom of turbine choice. The aluminum die-cast enclosure and the OptiCool active cooling system ensure optimal yield as well as a long service life, even under adverse operating conditions.¹ US-Patent US7352549B1
UL listed
For the North American small wind market (UL 1741/IEEE-1547)
Economical
Peak efficiency of 96.5 %
OptiCool active temperature management
Simple
Free choice of installation site
Programmable polynomial curve enables free selection of turbines
Secure
Galvanic isolation due to integrated transformer
208 V240 V 240 V
-Input (DC)
Max. DC power (@ cos φ = 1) 3200 W
Max. input voltage / rated input voltage 500 V / 250 V
Min. open-circuit voltage for “Turbine Mode†activation 230 V
“Turbine Mode†voltage range 175 V – 500 V200 V – 500 V
Max. input current 17 A
-Output (AC)
Rated power (@ 230 V, 50 Hz) 3000 W
Max. apparent AC power 3000 W
Nominal AC voltage / range 208 V / 183 V – 229 V240 V / 211 V – 264 V
AC power frequency / range 60 Hz / 59.3 Hz ... 60.5 Hz
Rated power frequency / rated grid voltage 60 Hz / 208 V60 Hz / 240 V
Max. output current 15 A13 A
Power factor at rated power 1
Feed-in phases / connection phases 1 / 2
-Efficiency
Max. efficiency / CEC efficiency 96 % / 95 %96.5 % / 95.5 %
-Protective devices
DC reverse polarity protection / AC short-circuit current capability yes / yes
Galvanically isolated yes
Protection class (according to IEC 62103) I
Overvoltage category (according to IEC 60664-1) III
-General data
Dimensions (W/H/D) 450 / 352 / 236 mm(17.7 / 13.9 / 9.3 inches)
Weight 40 kg / 88 lb
Operating temperature range -25 °C ... +45 °C /-13 °F ... +113 °F
Noise emission 40 db(A)
Topology LF transformer
Cooling concept OptiCool
Protection of electronics / connection area (according to IEC 60529) NEMA 3R / NEMA 3R
-Features
Display Text line
Interfaces: RS485 / Bluetooth opt. / opt.
Warranty: 10 years yes
Certificates and approvals (more available upon request) UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B)
The Windy Boy Protection Box can do it all: It protects the inverter from excess voltage by feeding excess generator voltage to a load resistance, which slows down&n
The Multicluster Boxes for Sunny Island 5048 allow the formation of off-grid and hybrid systems with a capacity of between 20 and 300 kW. As the main AC distrib
Commissioning just takes a few minutes: For Sunny Island 5048, the settings needed for operation can be configured in very few steps. It is flexible in its applicati
With a maximum efficiency of 95.6 percent, the Windy Boy 3300 and 3800 inverters are among the most cost-effective for small wind turbine systems. The weatherproof enclos
The Transformer Compact Station – now also for 900 kVA nominal power – is the ideal link between SMA central inverters and the medium-voltage grid. As a&nbs
With even better communication, usability and efficiency, the Windy Boy 3600TL and 5000 TL inverters set new standards. With a modern graphic display, a simplified mounting&nb
The Windy Boy Protection Box can do it all: It protects the inverter from excess voltage by feeding excess generator voltage to a load resistance, which slows down&n
The new OptiUse operating concept makes installation, commissioning and day-to-day use easier than ever before. The Quick Configuration Guide helps you complete the commissioning i
Systems using Sunny Island and Sunny Backup are now even more fl exible: to maximize the user convenience, we have moved the control unit on the outside of the&
The Windy Boy 5000A and 6000A feature a peak efficiency of 96.1 percent and are also suited for a threephase grid feed-in. The integrated SMA Power Balancer prevents