APC MGE Galaxy 3500 UPS G35T10KH2B2S

APC MGE Galaxy 3500 UPS G35T10KH2B2S
share

Specifications:
Output
Output Power Capacity 8000 Watts / 10 kVA
Max Configurable Power 8000 Watts / 10 kVA
Nominal Output Voltage 400V 3PH
Output Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Efficiency at Full Load 95.7%
Output Voltage Distortion Less than 5%
Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal
Other Output Voltages 380, 415
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
(1) Screw Terminals
Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
Output Voltage THD < 2% for 0 to 100% linear load and < 5% for full non linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 95.2%
Required Output Current Protection 16A
Bypass Built-in Maintenance Bypass, Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 304 - 477V
Input voltage adjustable range for mains operation 340 - 460 (400V)V
Other Input Voltages 380, 415
Maximum Input Current 14A
Input Breaker Capacity 16 A
Input Total Harmonic Distortion Less than 5% for full load
Type of Input Protection Required 3-pole breaker

APC Symmetra PX UPS SY400K500D
APC Symmetra PX UPS SY400K500D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 400 kW / 400 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Symmetra PX UPS SY50K100F
APC Symmetra PX UPS SY50K100F
Specifications:OutputOutput Power Capacity 50 kW / 50 kVAMax Configurable Power 100 kW / 100 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominalTopology Double Conversion OnlineWaveform Type Sine waveOutput
APC MGE Galaxy 3500 UPS G35TSBP10K15F
APC MGE Galaxy 3500 UPS G35TSBP10K15F
Specifications:OutputNominal Output Voltage 208V 3PHInputNominal Input Voltage 208V 3PHInput Frequency 60 HzPhysicalNet Weight 127.00 KGMaximum Height 1487.00 mmMaximum Width 351.00 mmMaximum Depth 837.00 mmShipping Weight 156.00 KGShipping Height 1663.00 mmShipping Width 723.00 mmShipping Depth 110
APC Smart-UPS SURT8000XLT
APC Smart-UPS SURT8000XLT
Specifications:OutputOutput Power Capacity 6400 Watts / 8000 VAMax Configurable Power 6400 Watts / 8000 VANominal Output Voltage 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageOutput Voltage Distortion Less than 3%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adj
APC Smart-UPS VT SUVTSBPAR20K30F
APC Smart-UPS VT SUVTSBPAR20K30F
Specifications:OutputNominal Output Voltage 208V 3PHInputNominal Input Voltage 208V 3PHInput Frequency 60 HzPhysicalNet Weight 171.00 KGMaximum Height 1487.00 mmMaximum Width 533.00 mmMaximum Depth 837.00 mmShipping Weight 205.00 KGShipping Height 1663.00 mmShipping Width 723.00 mmShipping Depth 110
APC Smart-UPS VT SUVTP15KF2B2S
APC Smart-UPS VT SUVTP15KF2B2S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.0%Output Voltage Distortion Less than 5% at full loadOutput Frequency (sync t
APC Smart-UPS VT SUVTP15KF3B4S
APC Smart-UPS VT SUVTP15KF3B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.0%Output Voltage Distortion Less than 5% at full loadOutput Frequency (sync t
APC MGE EPS 8000 UPS E8TUPS625
APC MGE EPS 8000 UPS E8TUPS625
Specifications:GeneralBypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G)Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 950AOutputOutput Power Capacity 562 kW / 625 kVAMax Configurable Power 562 kW / 625 kVANominal Output Voltage 480V 3PH, 600V 3PHOutpu
APC Symmetra PX UPS SY125K500DR-PD
APC Symmetra PX UPS SY125K500DR-PD
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 125 kW / 125 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Smart-UPS VT SUVTR40KH5B5S
APC Smart-UPS VT SUVTR40KH5B5S
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 96.0%Output Voltage Distortion Less than 5% at full loadOutput Fr