Undervoltage Alarm Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 100 W , Output 24 V 4.5 A
Power rating 100 W
Efficiency 82% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 1.4 A Max. ï¼ˆAt 100 VAC input)0.7 A Max. ï¼ˆAt 200 VAC input)
Power factor 0.98 Min. (At 100 VAC input)0.94 Min. (At 200 VAC input)
Harmonic Current EN61000-3-2
Leakage current 0.4 mA Max. (At 100 VAC input)0.75 mA Max. (At 200 VAC input)
Inrush current 17.5 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))35 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Output voltage variable range -10 to +20% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +20% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 0.75%(p-p) Max.
Static input variation influence 0.4% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.02 %/CEL Max. (At rated input/output voltage)
Rated output current 4.5 A
Start up time 800 ms Max. ï¼ˆAt rated input/output voltage)
Hold time 20 ms TYP.
Overload protection 105% to 160% of the rated output currentInverted L voltage drop, Automatic reset
Overvoltage protection Operated at 140% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output Yes (open collector output), 30 VDC Max., 50 mA Max., Sinking (NPN)
Power failure alarm indication No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function Yes
Applicable standard (UL) Standard No.: UL508 (Listing), UL60950-1, UL1604 (Listing, Class I / Division 2)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.14, No.213 (Class I / Division 2), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class B
Applicable standard(SEMI) F47-0200 (200 VAC input)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 30 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE/FG terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE/FG terminals: 500 VAC for 1 min (Detection current: 100 mA)Between all outputs (except the detection output terminals) and all detection output terminals: 500 VAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE/FG terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Mounting type DIN Rail mounting type
Attachment Instruction manual / Housing / Terminal

Omron S8JX Switch Mode Power S8JX-G01524
Omron S8JX Switch Mode Power S8JX-G01524
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 24V 0.65A , Front-mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated input voltage 100 to
Omron Power Supply S8VS Series S8VS-09024BPS-F
Omron Power Supply S8VS Series S8VS-09024BPS-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 90 WEfficiency 83%&nbs
Omron Power Supply S8EX Series S8EX-BP15024LC
Omron Power Supply S8EX Series S8EX-BP15024LC
With chassis and cover , Input 100 to 240 VAC , 150W , Output 24V 6.3APower rating 150 WEfficiency 84% Min. ï¼ˆAt 100 VAC input)87% Min. ï¼ˆAt 200 VAC in
Omron Power Supply S8JX Switch Mode Power S8JX-G10012
Omron Power Supply S8JX Switch Mode Power S8JX-G10012
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 12V 8.5A , Front-mounting typePower rating 100 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-input vol
Omron Power Supply S8VS Series S8VS-09024-F
Omron Power Supply S8VS Series S8VS-09024-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt&nbs
Omron S8JX Switch Mode Power S8JX-G01505
Omron S8JX Switch Mode Power S8JX-G01505
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 5V 3A , Front-mounting typePower rating 15 WEfficiency 68% Min.Rated input voltage 100 to 240 VACAllowable-input voltage&
Omron Power Supply S8VM Series S8VM-05015D
Omron Power Supply S8VM Series S8VM-05015D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 50 W , Output 15 V 3.5 APower rating 50 WEfficiency 79% Min.Rated 
Omron Power Supply S8JX Switch Mode Power S8JX-G10005CD
Omron Power Supply S8JX Switch Mode Power S8JX-G10005CD
Covered type , Input 100 to 240 VAC , 100 W , Output 5 V 20 A , DIN Rail mounting typePower rating 100 WEfficiency 76% Min.Rated input voltage 100 to 240 V
Omron Power Supply S8VS Series S8VS-01512
Omron Power Supply S8VS Series S8VS-01512
Total Run Time Monitor , Input 100 to 240 VAC , 120 W , Output 24 V 5 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 120 WEfficiency 83% TYP. 
Omron Power Supply S8VS Series S8VS-09024BE-F
Omron Power Supply S8VS Series S8VS-09024BE-F
Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 200