POWERWARE 9150 UPS 15I-NC-0

POWERWARE 9150 UPS 15I-NC-0
share

Specifications:
Rating 8-15 kVA at computer load
Efficiency Up to 93% online
Audible noise <50 dB (A)
Input Nominal voltage 230/400 V (Three-phase model)
230 V (Single-phase model)
Frequency 40-70 Hz
Power factor 0,96
Output Selectable voltage 220/230/240 VAC; 50 or 60 Hz
Regulation ±2% static
Overload Inverter 150% for 30 sec

Eaton Powerware 5110 UPS 51100350A
Eaton Powerware 5110 UPS 51100350A
Specifications:Capacity 350VA/210W Dimensions (mm) HxWxD 270x87x260Unit Weight (kg) 5 6 8 12 12.5Input Connection 1.8 metre line cord IEC to Australian 10Amp PlugOutput Connection 6 Australian 10Amp Outlets (3 Battery Backup & Surge Protection,3 Surge Protection only)OperationInput Voltage Range (on
Powerware 5125 RM UPS 51256000IRM
Powerware 5125 RM UPS 51256000IRM
Technical SpecificationsRating 6000VACapacity (VA/watts) 6000/5400Dimensions WxDxH (mm) 445x661x133Weight (kg) 73Input connection IEC309/32AOutput connection IEC309 32 A plug(4) IEC 320 16 A(4) IEC 320 10 A1 x IEC320/16ATypical Runtime (full load) pf 0.9 (half load)5 min 15 min
Powerware 5119 Rackmount UPS PW5119 3000RM
Powerware 5119 Rackmount UPS PW5119 3000RM
Specifications:Electrical InputVoltage 120 and 230 VAC NominalOn Line Voltage Range -30%, +20% for nominal voltages; user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)Nominal Input Frequency 50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)Frequency Tolerance No
Powerware 9104 UPS RST52
Powerware 9104 UPS RST52
Descriptions:The Powerware 9104 uninterruptible powersystem (UPS) provides quality power protectionranging from 3.1 to 6 kVA. Using dual-conversiononline technology, this UPS delivers excellentvoltage regulation, bi-directional filtering toeliminate power line noise, and low input currentdistortion.
Powerware 5125 RM UPS 51253000ERMBLK
Powerware 5125 RM UPS 51253000ERMBLK
Technical SpecificationsRating 3000VACapacity (VA/watts)3000/2700Dimensions WxDxH (mm) 483x622x89 Weight (kg) 46Input connection IEC320/16AOutput connection 9 x IEC320/10A1 x IEC320/16ATypical Runtime (full load) pf 0.9 (half load)5 min 15 min
Powerware 5119 UPS PW5119 1500
Powerware 5119 UPS PW5119 1500
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Powerware 5125 RM UPS 51251500IRMBLK
Powerware 5125 RM UPS 51251500IRMBLK
Technical SpecificationsRating 1500VACapacity (VA/watts) 1500/1350 Dimensions WxDxH (mm) 432x494x89 Weight (kg) 27 Input connection IEC320/10AOutput connection 6 x IEC320/10A Typical Runtime (full load) pf 0.9 (half load)5 min 14 min5 min
Powerware BPIII HE UPS 75 kVA/60 kw
Powerware BPIII HE UPS 75 kVA/60 kw
Specifications:Configuration: 3-Phase, 3 wire plus groundRange Nominal +10%, –15%Frequency range Nominal ±3 Hz (60 Hz)Power factor Minimum 0.9 with filterPower walk-in 3-60 seconds to full loadInput current 10% THD under nominal conditions distortion with filterTransient protection 6kV OC, 3 kV S
Powerware 9305 UPS PW9305-80I-N
Powerware 9305 UPS PW9305-80I-N
Specifications:Rating 80 kVA Capacity (VA/Watts)80 kVA/56 kWDimensions WxDxH (mm) 520x788x1530Weight (kg) 280Input connection Hardwired Output connection HardwiredTypical runtime (Full load) 12 min (Half load) 30 min
Powerware 5119 UPS PW5119 1000
Powerware 5119 UPS PW5119 1000
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc