Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / Powerware UPS Power Supply / Eaton Powerware 5110 UPS 51100350A

Eaton Powerware 5110 UPS 51100350A

Eaton Powerware 5110 UPS 51100350A
share

Specifications:
Capacity 350VA/210W
Dimensions (mm) HxWxD 270x87x260
Unit Weight (kg) 5 6 8 12 12.5
Input Connection 1.8 metre line cord IEC to Australian 10Amp Plug
Output Connection 6 Australian 10Amp Outlets (3 Battery Backup & Surge Protection,
3 Surge Protection only)
Operation
Input Voltage Range (on-line operation) 186 to 280 VAC
Output Voltage Regulation on-line 216 to 260 VAC
On Battery Output Voltage Nominal -12% to +10%
Frequency 50 Hz

Powerware 3110 UPS PW3110 300
Powerware 3110 UPS PW3110 300
Descriptions:Ideal for PC-based applications, the Powerware 3110 provides affordable protection in a sleek, well-designed unit that can fit undera desk or can be wall-mounted.
Powerware 9320-C03 UPS
Powerware 9320-C03 UPS
Descriptions:the Powerware 9320 offersall three in a modular, scalableUPS. The Powerware 9320 isdesigned to provide redundancyas well as the ability to increasesystem capacity as your needschange by using 10 or 20 kVAmodules in a single cabinet
Powerware 3110 UPS PW3110 300i
Powerware 3110 UPS PW3110 300i
Descriptions:Ideal for PC-based applications, the Powerware 3110 provides affordable protection in a sleek, well-designed unit that can fit undera desk or can be wall-mounted.
Powerware 5119 UPS PW5119 2000i
Powerware 5119 UPS PW5119 2000i
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Powerware Plus18 UPS Model 15
Powerware Plus18 UPS Model 15
Specifications: Input Frequency Range 45-65 Hz Power Factor 0.95 Typical at full load Output Voltage Regulation Better than +/- 3% Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load)Transient Response Less than 5% for 100% load, step full recovery within 1/4 cycl
Powerware 9120 UPS PW9120 3000
Powerware 9120 UPS PW9120 3000
Descriptions:The Powerware 9120 UPS is designed for those applicationsthat need maximum protection in the 700 VA – 3 kVA range.With its high-frequency, doubleconversion online topology, providingnonstop clean sine wave power, advanced communicationsand space-saving tower design, the Powerware 9120
Powerware 9125 UPS PW9125 700i
Powerware 9125 UPS PW9125 700i
Descriptions:the Powerware 9125 UPS delivers the ultimate in protection,truly isolating your equipment from all nine of the commonpower anomalies lurking in public utility power. Availableas either a rackmount or stand-alone unit, the compactand elegant 9125 supplies continuous, conditioned powerto
Powerware 5119 UPS PW5119 1000
Powerware 5119 UPS PW5119 1000
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Powerware BPII HE UPS 30 kVA/24 kw
Powerware BPII HE UPS 30 kVA/24 kw
Descriptions:Balanced Power II HE and Balanced Power II-S HE (BPII HE and BPII-S HE) offer the reliability of true online technology utilizing digital signal processing (DSP) control and monitoring. In addition, the BPII HE and BPII-S HE use the patented technology of an inverter software harmonic c
Powerware BPIII HE UPS 75 kVA/60 kw
Powerware BPIII HE UPS 75 kVA/60 kw
Specifications:Configuration: 3-Phase, 3 wire plus groundRange Nominal +10%, –15%Frequency range Nominal ±3 Hz (60 Hz)Power factor Minimum 0.9 with filterPower walk-in 3-60 seconds to full loadInput current 10% THD under nominal conditions distortion with filterTransient protection 6kV OC, 3 kV S