Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / Powerware UPS Power Supply / Powerware 5119 Rackmount UPS PW5119 2000RM

Powerware 5119 Rackmount UPS PW5119 2000RM

Powerware 5119 Rackmount UPS PW5119 2000RM
share

Specifications:
Electrical Input
Voltage 120 and 230 VAC Nominal
On Line Voltage Range -30%, +20% for nominal voltages;
user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)
Nominal Input Frequency
50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)
Frequency Tolerance Nominal +/-3 Hz
Electrical Output
Power Levels 1000-3000 VA
On Line Regulation
-10%, +6%; within Computer Business Equipment Manufacturers
Association's Guidelines (-15%; +10% using extended range)
On Battery Regulation < +/-5% RMS

POWERWARE 9150 UPS 12I-S-10
POWERWARE 9150 UPS 12I-S-10
Specifications:Rating 8-15 kVA at computer loadEfficiency Up to 93% onlineAudible noise
Powerware 3110 UPS PW3110 300
Powerware 3110 UPS PW3110 300
Descriptions:Ideal for PC-based applications, the Powerware 3110 provides affordable protection in a sleek, well-designed unit that can fit undera desk or can be wall-mounted.
Powerware BPIII Industrial UPS 30-160 KVA
Powerware BPIII Industrial UPS 30-160 KVA
Specifications:Configuration 3-phase, 3-wire plus groundRange Nominal +10%, -15%Frequency range Nominal ±3 Hz (60 Hz)Power factor Minimum 0.9with filterPower walk-in 3 to 60 seconds to full loadInput current 10% THD under nominal conditionsdistortion with filterTransient protection 6 kV OC, 3 kA pe
Eaton Powerware 5110 UPS 51100350A
Eaton Powerware 5110 UPS 51100350A
Specifications:Capacity 350VA/210W Dimensions (mm) HxWxD 270x87x260Unit Weight (kg) 5 6 8 12 12.5Input Connection 1.8 metre line cord IEC to Australian 10Amp PlugOutput Connection 6 Australian 10Amp Outlets (3 Battery Backup & Surge Protection,3 Surge Protection only)OperationInput Voltage Range (on
Powerware 9170 Online UPS PW6S9K-PD
Powerware 9170 Online UPS PW6S9K-PD
Specifications:Technical InformationPlug/Connector Type HardwiredReceptacles 2 x NEMA L14-30R2 x NEMA L6-30R12 x NEMA 5-20RPower DescriptionLoad Capacity 9 kVA/6.30 kWInput Voltage 110 V AC/220 V ACInput Voltage Range 120 V AC/208 V AC/240 V ACOutput Voltage 120 V AC/208 V AC/240 V ACFrequency 50 Hz
Powerware BPII HE UPS 30 kVA/24 kw
Powerware BPII HE UPS 30 kVA/24 kw
Descriptions:Balanced Power II HE and Balanced Power II-S HE (BPII HE and BPII-S HE) offer the reliability of true online technology utilizing digital signal processing (DSP) control and monitoring. In addition, the BPII HE and BPII-S HE use the patented technology of an inverter software harmonic c
Powerware 9315-160 UPS Model 130 130kVA/104kW
Powerware 9315-160 UPS Model 130 130kVA/104kW
Specifications:InputVoltage range: (See chart on other side)Frequency range: (60 Hz) 57-63 Hz; (50 Hz) 47-53HzPower factor: 0.95 typical at full load with inputfilter. Input current distortion lessthan 7% with input filtOutputVoltage regulation: Better than ±1%Transient response: Less than 5% for 1
Powerware 9330 UPS Model 25 25kVA/17.5kW
Powerware 9330 UPS Model 25 25kVA/17.5kW
Descriptions: the Powerware 9330 offers the highest reliability for critical systems in this power range.And provides IT managers with a state-of-the-art UPS designed for optimal efficiency and the highest reliability. Powerware 9330 delivers the highest performance by using digital signal
Powerware 9305 UPS PW9305-10I-N
Powerware 9305 UPS PW9305-10I-N
Specifications:Rating 10 kVA Capacity (VA/Watts) 10 / 7Dimensions WxDxH (mm) 400x750x700 Weight (kg) 180 Input connection Hardwired Output connection HardwiredTypical runtime (Full load) 14 min (Half load) 7 min
Powerware Plus18 UPS Model 12
Powerware Plus18 UPS Model 12
Specifications: Input Frequency Range 45-65 Hz Power Factor 0.95 Typical at full load Output Voltage Regulation Better than +/- 3% Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load)Transient Response Less than 5% for 100% load, step full recovery within 1/4 cycl