Powerware 5125 RM UPS 51256000IRM

Powerware 5125 RM UPS 51256000IRM
share

Technical Specifications
Rating 6000VA
Capacity (VA/watts) 6000/5400
Dimensions WxDxH (mm) 445x661x133
Weight (kg) 73
Input connection IEC309/32A
Output connection IEC309 32 A plug
(4) IEC 320 16 A
(4) IEC 320 10 A
1 x IEC320/16A
Typical Runtime (full load) pf 0.9 (half load)5 min 15 min

Powerware BPII-S HE UPS 30 kVA/24 kw
Powerware BPII-S HE UPS 30 kVA/24 kw
Descriptions:Balanced Power II HE and Balanced Power II-S HE (BPII HE and BPII-S HE) offer the reliability of true online technology utilizing digital signal processing (DSP) control and monitoring. In addition, the BPII HE and BPII-S HE use the patented technology of an inverter software harmonic c
Powerware 5119 UPS PW5119 1000
Powerware 5119 UPS PW5119 1000
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Powerware BPIII HE UPS 75 kVA/60 kw
Powerware BPIII HE UPS 75 kVA/60 kw
Specifications:Configuration: 3-Phase, 3 wire plus groundRange Nominal +10%, –15%Frequency range Nominal ±3 Hz (60 Hz)Power factor Minimum 0.9 with filterPower walk-in 3-60 seconds to full loadInput current 10% THD under nominal conditions distortion with filterTransient protection 6kV OC, 3 kV S
Powerware 9125 UPS PW9125 1250i
Powerware 9125 UPS PW9125 1250i
Descriptions:the Powerware 9125 UPS delivers the ultimate in protection,truly isolating your equipment from all nine of the commonpower anomalies lurking in public utility power. Availableas either a rackmount or stand-alone unit, the compactand elegant 9125 supplies continuous, conditioned powerto
Powerware 9170 Online UPS PW12S15K
Powerware 9170 Online UPS PW12S15K
Specifications:Technical InformationPlug/Connector Type HardwiredReceptacles HardwiredPower DescriptionLoad Capacity 15 kVA/10.50 kWInput Voltage 110 V AC/220 V ACInput Voltage Range 120 V AC/208 V AC/220 V ACOutput Voltage 120 V AC/208 V AC/240 V ACFrequency 50 Hz/60 HzWaveform Type Sine WaveScalab
Powerware Plus18 UPS Model 18
Powerware Plus18 UPS Model 18
Specifications: Input Frequency Range 45-65 Hz Power Factor 0.95 Typical at full load Output Voltage Regulation Better than +/- 3% Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load)Transient Response Less than 5% for 100% load, step full recovery within 1/4 cycl
Eaton-Powerware 3105 UPS 103004250-5592
Eaton-Powerware 3105 UPS 103004250-5592
Specifications:Rating (VA/Watts) 500/300Dimensions (H x W x D, inches) 4.4 x 7 x 11Weight (lbs) 11.2Electrical InputConnection (1) NEMA 5-15PInput Cord 6-foot line cord with 90° 5-15PInput Voltage Range 0-160 VacNominal Voltage 120 VACElectrical OutputOutput Receptacles (4) NEMA 5-15R(4) NEMA 5-15R
Powerware 5140 Rack-mount UPS PW5140 6000i
Powerware 5140 Rack-mount UPS PW5140 6000i
Specifications:Power Rating: 6000VA/6000WattsVoltage:200-240 VFrequency:50 and 60HzConfiguration:6U rackmount for standard 19-inch racksTopology: Line-interactive (with pure sine wave output)
Powerware 5119 UPS PW5119 1000
Powerware 5119 UPS PW5119 1000
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Powerware Plus18 UPS Model 12
Powerware Plus18 UPS Model 12
Specifications: Input Frequency Range 45-65 Hz Power Factor 0.95 Typical at full load Output Voltage Regulation Better than +/- 3% Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load)Transient Response Less than 5% for 100% load, step full recovery within 1/4 cycl