Specifications:
Electrical Input
Voltage 120 and 230 VAC Nominal
On Line Voltage Range -30%, +20% for nominal voltages;
user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)
Nominal Input Frequency
50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)
Frequency Tolerance Nominal +/-3 Hz
Electrical Output
Power Levels 1000-3000 VA
On Line Regulation
-10%, +6%; within Computer Business Equipment Manufacturers
Association's Guidelines (-15%; +10% using extended range)
On Battery Regulation < +/-5% RMS

Powerware 9120 UPS PW9120 2000i
Powerware 9120 UPS PW9120 2000i
Descriptions:The Powerware 9120 UPS is designed for those applicationsthat need maximum protection in the 700 VA – 3 kVA range.With its high-frequency, doubleconversion online topology, providingnonstop clean sine wave power, advanced communicationsand space-saving tower design, the Powerware 9120
POWERWARE 9150 UPS 12I-SC-0
POWERWARE 9150 UPS 12I-SC-0
Specifications:Rating 8-15 kVA at computer loadEfficiency Up to 93% onlineAudible noise
Powerware BPIII 300 Industrial UPS 225-300 kVA
Powerware BPIII 300 Industrial UPS 225-300 kVA
Specifications:Input SpecificationsFrequency range: (60 Hz) 57-63 HzSurge protection: Meets ANSI C62.41Category A & B: EN 50091-2, and EN 50082-2Power factor: 0.95 typical at full load with input filterInput currentdistortion: less than 7% with input filterOutput SpecificationsVoltage THD: Less than
Powerware BPII HE UPS 10 kVA/8 kw
Powerware BPII HE UPS 10 kVA/8 kw
Descriptions:Balanced Power II HE and Balanced Power II-S HE (BPII HE and BPII-S HE) offer the reliability of true online technology utilizing digital signal processing (DSP) control and monitoring. In addition, the BPII HE and BPII-S HE use the patented technology of an inverter software harmonic c
Powerware 9120 UPS PW9120 3000h
Powerware 9120 UPS PW9120 3000h
Descriptions:The Powerware 9120 UPS is designed for those applicationsthat need maximum protection in the 700 VA – 3 kVA range.With its high-frequency, doubleconversion online topology, providingnonstop clean sine wave power, advanced communicationsand space-saving tower design, the Powerware 9120
Powerware BPIV Industrial UPS 20 kVA/18 kw
Powerware BPIV Industrial UPS 20 kVA/18 kw
Descriptions:The BPIV delivers enhanced backup power, power quality, and system reliability with the highest efficiency ratings of any online UPS in the 10-30 kVA range for industrial equipment. Powerware Industrial UPS systems offer cost savings with the best power protection.
Powerware 5119 UPS PW5119 1500i
Powerware 5119 UPS PW5119 1500i
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Powerware 9305 UPS PW9305-7.5I-N
Powerware 9305 UPS PW9305-7.5I-N
Specifications:Rating 7.5 kVA Capacity (VA/Watts) 7.5 / 5.25 Dimensions WxDxH (mm) 400x750x700 Weight (kg) 180 Input connection Hardwired Output connection HardwiredTypical runtime (Full load) 18 min (Half load) 40 min
Powerware 9125 Rackmount UPS 91251000iRM
Powerware 9125 Rackmount UPS 91251000iRM
Specifications:Rating 1000VA Capacity (VA/Watts) 1000/700 Dimensions WxDxH (mm) 432x490x89 Weight (kg) 15Input Connection IEC320/10AOutput Connection 6xIEC320 10A OperationalNominal input voltage (Vac) 220/230/240 VacInput voltage range 160-288 VAC
Powerware Plus18 UPS Model 15
Powerware Plus18 UPS Model 15
Specifications: Input Frequency Range 45-65 Hz Power Factor 0.95 Typical at full load Output Voltage Regulation Better than +/- 3% Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load)Transient Response Less than 5% for 100% load, step full recovery within 1/4 cycl