Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / inverter / SAM / Solar Inverters with Transformer / SMA Solar Inverters with Transformer SUNNY BOY 3000-US

SMA Solar Inverters with Transformer SUNNY BOY 3000-US

SMA Solar Inverters with Transformer SUNNY BOY 3000-US
share

Specially designed for countries that require UL listing, these Sunny Boy inverters guarantee a safe installation process thanks to the automatic grid voltage detection¹. The integrated DC circuit breaker simplifies the installation process and saves installation costs. Since the devices are suitable for PV array grounding, they can be combined with all module types. In addition, OptiCool guarantees the highest yields possible and a long electrical endurance, even under extreme conditions. The Sunny Boy 3800-US is designed for projects with a current limit of 16 A.
UL listed
For countries that require UL listing (UL 1741/IEEE 1547/CAN CSA C22.2 107)
Economical
96.8 % peak efficiency
OptiCool active temperature management
Reliable
Galvanic isolation
Arc-fault circuit interrupter (AFCI), optional
Simple
Automatic grid voltage detection¹
Integrated DC switch-disconnector
208 V240 V
-Input (DC)
Max. recommended PV power (@ module STC) 3750 W
Max. DC power (@ cos Ï† = 1) 3200 W
Max. input voltage 500 V
MPP voltage range / rated input voltage 200 V â€“ 400 V / 250 V
Min. input voltage / initial input voltage 175 V / 228 V
Max. input current 17 A
Max. string fuse on the DC disconnector 20 A
Number of independent MPP inputs 1
Strings per MPP input (@ DC disconnector) 4
-Output (AC)
Rated power / max. apparent AC power 3000 W / 3000 VA3000 W / 3000 VA
Nominal AC voltage / nominal AC voltage range 208 V / 183 V â€“ 229 V240 V / 211 V â€“ 264 V
AC power frequency / range 60 Hz / 59.3 Hz ... 60.5 Hz
Max. output current 15 A13 A
Power factor at rated power 1
Feed-in phases / connection phases 1 / 2
CEC efficiency / max. efficiency 95 % / 96 %95.5 % / 96.5 %
-Protective devices
DC reverse polarity protection yes
AC short-circuit current capability yes
Galvanically isolated yes
Arc-fault circuit interrupter (according to UL 1699B)¹ opt.
Protection class (according to IEC 62103) I
Overvoltage category (according to IEC 60664-1) III
-General data
Dimensions (W / H / D) 450 / 350 / 235 mm(17.8 / 13.8 / 9.3 inch)
Dimensions of DC Disconnect (W / H / D) 187 / 297 / 190 mm(7.3 / 11.7 / 7.5 inch)
Weight 38 kg / 84 lb
Weight of DC Disconnect 3.5 kg / 8 lb
Operating temperature range¹ -25 °C ... +45 °C /-13 °F ... +113 °F
Noise emission (typical) 40 dB(A)
Self-consumption (night) 0.1 W
Topology LF transformer
Cooling concept OptiCool
Degree of protection NEMA 3R
Degree of protection of connection area NEMA 3R
Max. permissible value for relative humidity (non-condensing) 100 %
-Features
DC connection Screw terminal
AC connection Screw terminal
Display Text line
Interface: RS485 / Bluetooth opt. / opt.
Warranty: 10 / 15 / 20 years yes / opt. / opt.
Certificates and approvals (more available on request) UL1741, UL1998, IEEE1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1, C22.2, UL 1699B

SAM Solar Inverters without Transformer SUNNY TRIPOWER 17000TL
SAM Solar Inverters without Transformer SUNNY TRIPOWER 17000TL
Optiflex is the first of our new features.Its outstanding flexibility opens up endless possibilities.How? Through an asymmetrically dimensioned multistring input combined with a broad&n
SMA Solar Inverters with Transformer SUNNY MINI CENTRAL 7000HV
SMA Solar Inverters with Transformer SUNNY MINI CENTRAL 7000HV
More modules can be connected in series with the Sunny Mini Central 7000HV than with common inverters. This reduces cabling costs on the DC side and simplifies the&n
SMA Solar Inverters with Transformer SUNNY BOY 2500
SMA Solar Inverters with Transformer SUNNY BOY 2500
Universally applicable: the Sunny Boy inverters 1200, 1700, 2500 and 3000 are used in the most diverse AC grids thanks to their galvanic isolation. In addition, the 
SAM Solar Inverters without Transformer SUNNY BOY 5000TL RPC
SAM Solar Inverters without Transformer SUNNY BOY 5000TL RPC
Electrifying detail: Thanks to the higher, 750 volt maximum DC input voltage, often times one less module string is needed because more modules can be switched on in
SMA Solar Inverters with Transformer SUNNY BOY 3800-US
SMA Solar Inverters with Transformer SUNNY BOY 3800-US
Specially designed for countries that require UL listing, these Sunny Boy inverters guarantee a safe installation process thanks to the automatic grid voltage detection¹. The 
SMA Solar Inverters with Transformer SUNNY BOY 7000-US
SMA Solar Inverters with Transformer SUNNY BOY 7000-US
Maximum energy yields for a continuously expanding photovoltaic market: the Sunny Boys with UL listing is impressive with its excellent efficiency. Graduated power classes provide&
SMA Solar Inverters with Transformer SUNNY BOY 3000
SMA Solar Inverters with Transformer SUNNY BOY 3000
Universally applicable: the Sunny Boy inverters 1200, 1700, 2500 and 3000 are used in the most diverse AC grids thanks to their galvanic isolation. In addition, the 
SAM Solar Inverters without Transformer SUNNY TRIPOWER 12000TL
SAM Solar Inverters without Transformer SUNNY TRIPOWER 12000TL
Optiflex is the first of our new features.Its outstanding flexibility opens up endless possibilities.How? Through an asymmetrically dimensioned multistring input combined with a broad&n
SMA Solar Inverters with Transformer SUNNY BOY 4000-US
SMA Solar Inverters with Transformer SUNNY BOY 4000-US
Specially designed for countries that require UL listing, these Sunny Boy inverters guarantee a safe installation process thanks to the automatic grid voltage detection¹. The 
SAM Solar Inverters without Transformer SUNNY BOY 11000TL-US
SAM Solar Inverters without Transformer SUNNY BOY 11000TL-US
With peak efficiencies of 98.3%, the transformerless Sunny Boy TL-US provide their owners with high yields. The power classes, finely tiered from 6 kW to 11kW, are i