Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / APC UPS Power Supply / APC MGE Galaxy 5000 UPS / APC MGE Galaxy 5000 UPS SUG550S90UL

APC MGE Galaxy 5000 UPS SUG550S90UL

APC MGE Galaxy 5000 UPS SUG550S90UL
share

Specifications:
Output
Output Power Capacity 45 kW / 50 kVA
Max Configurable Power 45 kW / 0 VA
Nominal Output Voltage 480V 3PH, 600V 3PH
Efficiency at Full Load 93.3%
Output Voltage Distortion Less than 5%
Output Frequency (sync to mains) 60 Hz
Crest Factor 3 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
Output Voltage Tolerance +/- 1% static and +/- 2 % at 100% load step
Output Voltage THD < 1% linear load and < 2.5% nonlinear load
Overload Operation 10 minutes @ 125% and 30 seconds @ 150%
Efficiency at Half Load 91.0%
Bypass Internal Bypass (Automatic and Manual), Optional External Bypass
Input
Nominal Input Voltage 480V 3PH, 600V 3PH
Input Frequency 45 - 65 Hz
Input Connections
Hard Wire 4-wire (3PH + G)
Input voltage range for main operations 408 - 552 (480)V
Maximum Input Current 60A
Input Breaker Capacity 200 A
Maximum Short Circuit Withstand (Icw) 20.0 kA
Input Total Harmonic Distortion Less than 5% for full load
Type of Input Protection Required 3-pole breaker

APC MGE Galaxy 5000 UPS G5TUPS50
APC MGE Galaxy 5000 UPS G5TUPS50
Specifications:GeneralBypass Connection 4 wire (3Ph + N)OutputOutput Power Capacity 45 kW / 50 kVAMax Configurable Power 45 kW / 80 kVANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 93.0%Output Frequency (sync to mains) 60 HzTopology Double Conversion OnlineWaveform Type Sine waveO
APC MGE Galaxy 3500 UPS G35T20KH2B2S
APC MGE Galaxy 3500 UPS G35T20KH2B2S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.7%Output Voltage Distortion Less than 5%Output Frequency (sync
APC Symmetra PX UPS SY400K500D
APC Symmetra PX UPS SY400K500D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 400 kW / 400 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Symmetra UPS SYH4K6RMT
APC Symmetra UPS SYH4K6RMT
Specifications:OutputOutput Power Capacity 2800 Watts / 4000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 89.0%Output Voltage Distortion Less than 5% at full loadOutput Frequency
APC Smart-UPS SURT10KRMXL6U-TF5
APC Smart-UPS SURT10KRMXL6U-TF5
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 92.0%Output Voltage Distortion Less than 3%Output Frequency (sync to
APC MGE Galaxy 3500 UPS G35T20KH4B4S
APC MGE Galaxy 3500 UPS G35T20KH4B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.7%Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nomina
APC Smart-UPS VT SUVTP40KH4B4S
APC Smart-UPS VT SUVTP40KH4B4S
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 96.0%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Back-UPS BK350EI
APC Back-UPS BK350EI
Back-UPS Describtion:APC Back-UPS,210 Watts /350 VA,Input 230V /Output 230V, Interface Port Optional Simple Signalling RS232 cable, USBIncludes: CD with software, Documentation CD, Qty 1 - Detachable 1.2 m IEC power cord, Qty 1 - Detachable 1.8 m IEC power cord, Telephone Cable, USB cable, Warran
APC MGE EPS 8000 UPS E8TUPS625
APC MGE EPS 8000 UPS E8TUPS625
Specifications:GeneralBypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G)Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 950AOutputOutput Power Capacity 562 kW / 625 kVAMax Configurable Power 562 kW / 625 kVANominal Output Voltage 480V 3PH, 600V 3PHOutpu
APC Smart-UPS VT SUVTP15KF2B4S
APC Smart-UPS VT SUVTP15KF2B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.0%Output Voltage Distortion Less than 5% at full loadOutput Frequency (sync t