Specifications:
Output
Output Power Capacity 36 kW / 40 kVA
Max Configurable Power 36 kW / 40 kVA
Nominal Output Voltage 400V 3PH, 480V 3PH, 600V 3PH
Output Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Efficiency at Full Load 91.1%
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50 Hz - programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8%, 60 Hz
Other Output Voltages 380, 400, 415, 600
Crest Factor 3 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/- 1% static and +/- 2 % at 100% load step
Output Voltage THD < 1% linear load and < 2.5% nonlinear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 85.6%
Neutral Output Current 87A
Bypass Internal Bypass (Automatic and Manual), Optional External Bypass
Input
Nominal Input Voltage 400V 3PH, 480V 3PH, 600V 3PH
Input Frequency 45 - 65 Hz
Input Connections
Hard Wire 4-wire (3PH + G)
Input voltage range for main operations 340 - 460 (400V), 408 - 538V
Other Input Voltages 380, 400, 415, 480, 600
Maximum Input Current 77A
Input Breaker Capacity 125 A
Maximum Short Circuit Withstand (Icw) 20.0 kA
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker

APC Smart-UPS SUA3000RM2U
APC Smart-UPS SUA3000RM2U
Smart-UPS specification:OutputOutput Power Capacity 2700 Watts / 3000 VAMax Configurable Power 2700 Watts / 3000 VANominal Output Voltage 110V, 120VOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal, 57 - 63 Hz for 60 Hz nominalTopology L
APC Smart-UPS SURT10000RMXLI
APC Smart-UPS SURT10000RMXLI
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageEfficiency at Full Load 92.0%Output Voltage Distortion Less than 3%Output Frequency (sync to
APC Galaxy VM UPS GVMPB225KGS
APC Galaxy VM UPS GVMPB225KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 350ABypass Protection Device 400AOutputOutput Power Capacity 202.5 kW / 225 kVAMax Configurable Power 202.5 kW / 225 kVANominal Output Voltage 480V 3PH
APC Smart-UPS SURT6000RMXLI
APC Smart-UPS SURT6000RMXLI
Specifications:OutputOutput Power Capacity 4200 Watts / 6000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageEfficiency at Full Load 92.0%Output Voltage Distortion Less than 3%Output Frequency (sync t
APC MGE Galaxy 3500 UPS G35T40KH4B4S
APC MGE Galaxy 3500 UPS G35T40KH4B4S
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync
APC Smart-UPS SURT15KRMXLT-1TF10K
APC Smart-UPS SURT15KRMXLT-1TF10K
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageOutput Voltage Distortion Less than 5%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adj
APC Symmetra PX UPS SY32K96H-NB
APC Symmetra PX UPS SY32K96H-NB
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 32 kW / 32 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase
APC Symmetra UPS SYA12K16P
APC Symmetra UPS SYA12K16P
Specifications:OutputOutput Power Capacity 9600 Watts / 12 kVAMax Configurable Power 12.8 kW / 16 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 120/208 or 120/240 output voltageOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 63 HzOt
APC MGE EPS 8000 UPS E8TUPS800
APC MGE EPS 8000 UPS E8TUPS800
Specifications:GeneralBypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G)Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 1215AOutputOutput Power Capacity 720 kW / 800 kVAMax Configurable Power 720 kW / 800 kVANominal Output Voltage 480V 3PH, 600V 3PHOutp
APC Smart-UPS SURT6000RMXLT3U
APC Smart-UPS SURT6000RMXLT3U
Specifications:OutputOutput Power Capacity 4200 Watts / 6000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 92.0%Output Voltage Distortion Less than 3%Output Frequency (sync to main