Specifications:
Output
Output Power Capacity 72 kW / 80 kVA
Max Configurable Power 72 kW / 0 VA
Nominal Output Voltage 480V 3PH, 600V 3PH
Efficiency at Full Load 92.8%
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 60 Hz
Crest Factor 3 : 1
Topology Double Conversion Online
Output Connections
(1) Hard Wire 4-wire (3PH + G)
Output Voltage Tolerance +/- 1% static and +/- 2 % at 100% load step
Output Voltage THD < 1% linear load and < 2.5% nonlinear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 90.0%
Required Output Current Protection 115A
Bypass Internal Bypass (Automatic and Manual), Optional External Bypass
Input
Nominal Input Voltage 480V 3PH, 600V 3PH
Input Frequency 45 - 65 Hz, 60 Hz +/- 5 Hz
Input Connections
Hard Wire 4-wire (3PH + G)
Input voltage range for main operations 408 - 552 (480)V
Maximum Input Current 152A
Input Breaker Capacity 250 A
Maximum Short Circuit Withstand (Icw) 20.0 kA
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker

APC Smart-UPS SMC1500-2U
APC Smart-UPS SMC1500-2U
Specifications:OutputOutput Power Capacity 900 Watts / 1440 VAMax Configurable Power 900 Watts / 1440 VANominal Output Voltage 120VOutput Voltage Distortion Less than 5%Output Frequency (sync to mains) 50/60Hz +/- 3 HzTopology Line InteractiveWaveform Type Sine waveOutput Connections(6) NEMA 5-15R N
 APC Symmetra MW UPS SYMF1200KG
APC Symmetra MW UPS SYMF1200KG
Specifications:OutputOutput Power Capacity 1.2 MW / 1.2 MVAMax Configurable Power 1.2 MW / 1.2 MVANominal Output Voltage 480V 3PHOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 60 Hz - programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8%Crest Factor UnlimitedTopology Delta C
APC MGE EPS 7000 UPS E7TUPS300
APC MGE EPS 7000 UPS E7TUPS300
Specifications:GeneralMax Bypass Input Current 361AOutputOutput Power Capacity 270 kW / 300 kVAMax Configurable Power 270 kW / 300 kVANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 93.5%Output Voltage Distortion Less than 2%Output Frequency (sync to mains) 60 HzOther Output Voltage
APC Symmetra PX UPS SY96K160H
APC Symmetra PX UPS SY96K160H
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 96 kW / 96 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase
APC Symmetra PX UPS SY10K40F
APC Symmetra PX UPS SY10K40F
Specifications:GeneralBypass Connection 5 wire 3PH + N +GMax Bypass Input Current 162ABypass Protection Device 175AOutputOutput Power Capacity 10 kW / 10 kVAMax Configurable Power 40 kW / 40 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 5%Output Frequency (sync to
APC Symmetra PX UPS SY150K250D
APC Symmetra PX UPS SY150K250D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 150 kW / 150 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Back-UPS BE650G1-LM
APC Back-UPS BE650G1-LM
Back-UPS specification:Output Power Capacity 390 Watts / 650 VAMax Configurable Power 390 Watts / 0 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50 Hz, 60 HzTopology StandbyWaveform Type Stepped approximation to a sinewaveOutput Connections(4) NEMA 5-15R (Battery Backup) NEMA 5-15R(
APC Smart-UPS VT SUVTP15KH2B4S
APC Smart-UPS VT SUVTP15KH2B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.7%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Smart-UPS VT SUVTR20KG4B5S
APC Smart-UPS VT SUVTR20KG4B5S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.8%Output Voltage Distortion Less than 5% at full lo
APC Smart-UPS SUA5000RMT5U
APC Smart-UPS SUA5000RMT5U
Destribtions:APC Smart-UPS,4000 Watts /5000 VA,Input 208V /Output 208V, Interface Port DB-9 RS-232, SmartSlot, Rack Height 5 UIncludes: CD with software, Rack Mounting support rails, Smart UPS signalling RS-232 cable, User Manual, Web/SNMP Management CardStandard Lead Time: Usually Ships within 3 We