Specifications:
Output
Output Power Capacity 72 kW / 80 kVA
Max Configurable Power 72 kW / 80 kVA
Nominal Output Voltage 400V 3PH, 480V 3PH, 600V 3PH
Output Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Efficiency at Full Load 92.8%
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50 Hz - programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8%
Other Output Voltages 380, 415
Crest Factor 3 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/- 1% static and +/- 2 % at 100% load step
Output Voltage THD < 1% linear load and < 2.5% nonlinear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 90.0%
Required Output Current Protection 115A
Bypass Internal Bypass (Automatic and Manual), Optional External Bypass
Input
Nominal Input Voltage 400V 3PH, 480V 3PH, 600V 3PH
Input Frequency 45 - 65 Hz
Input Connections
Hard Wire 4-wire (3PH + G)
Input voltage range for main operations 340 - 460 (400V), 408 - 538V
Other Input Voltages 380, 400, 415
Maximum Input Current 152A
Input Breaker Capacity 250 A
Maximum Short Circuit Withstand (Icw) 30.0 kA
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker

APC Galaxy VM UPS GVMSB180KGS
APC Galaxy VM UPS GVMSB180KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 217ABypass Protection Device 400AOutputOutput Power Capacity 162 kW / 180 kVAMax Configurable Power 162 kW / 180 kVANominal Output Voltage 480V 3PHOutp
APC Galaxy VM UPS GVMRB160KGS
APC Galaxy VM UPS GVMRB160KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 217ABypass Protection Device 400AOutputOutput Power Capacity 144 kW / 160 kVAMax Configurable Power 144 kW / 160 kVANominal Output Voltage 480V 3PHOutp
APC MGE Galaxy 5000 UPS SUG5100A90UL
APC MGE Galaxy 5000 UPS SUG5100A90UL
Specifications:OutputOutput Power Capacity 90 kW / 100 kVAMax Configurable Power 90 kW / 0 VANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 92.9%Output Voltage Distortion Less than 2%Output Frequency (sync to mains) 60 HzCrest Factor 3 : 1Topology Double Conversion OnlineWaveform T
APC MGE EPS 7000 UPS E7TUPS500
APC MGE EPS 7000 UPS E7TUPS500
Specifications:GeneralMax Bypass Input Current 601AOutputOutput Power Capacity 450 kW / 500 kVAMax Configurable Power 450 kW / 500 kVANominal Output Voltage 480V 3PH, 600V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 60 HzOther Output Voltages 600Crest Factor 3.5 : 1Topo
APC MGE Galaxy 3500 UPS G35T10KF2B4S
APC MGE Galaxy 3500 UPS G35T10KF2B4S
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.2%Output Voltage Distortion Less than 3%Output Freque
APC Back-UPS BX650U-LM
APC Back-UPS BX650U-LM
Back-UPS specification:Output Power Capacity 390 Watts / 650 VAMax Configurable Power 390 Watts / 650 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50/60Hz +/- 3 HzTopology Line InteractiveWaveform Type Stepped approximation to a sinewaveOutput Connections(4) NEMA 5-15R (Battery Back
APC Galaxy VM UPS GVMSBC450KG
APC Galaxy VM UPS GVMSBC450KG
Specifications:OutputNominal Output Voltage 480V 3PHInputNominal Input Voltage 480V 3PHInput Frequency 40 - 70 HzPhysicalNet Weight 1067.00 lbs. (485.00 kg)Maximum Height 77.56 inches (1970 mm)Maximum Width 59.25 inches (1505 mm)Maximum Depth 32.95 inches (837 mm)Shipping Weight 1235.00 lbs. (560.19
APC Smart-UPS VT SUVTP15KH2B2S
APC Smart-UPS VT SUVTP15KH2B2S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.7%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Smart-UPS VT SUVTP20KH2B4S
APC Smart-UPS VT SUVTP20KH2B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.3%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC MGE Galaxy 3500 UPS G35T40K3I4B4S
APC MGE Galaxy 3500 UPS G35T40K3I4B4S
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageEfficiency at Full Load 95.4%Output Voltage Distortion Less than 5%Output Frequency (sync to mains) 47