Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / APC UPS Power Supply / APC MGE Galaxy 5000 UPS / APC MGE Galaxy 5000 UPS SUG5100S90UL

APC MGE Galaxy 5000 UPS SUG5100S90UL

APC MGE Galaxy 5000 UPS SUG5100S90UL
share

Specifications:
General
Bypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G)
Output
Output Power Capacity 90 kW / 100 kVA
Max Configurable Power 90 kW / 0 VA
Nominal Output Voltage 480V 3PH, 600V 3PH
Efficiency at Full Load 92.9%
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 60 Hz
Other Output Voltages 600
Crest Factor 3 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
Output Voltage Tolerance +/- 1% static and +/- 2 % at 100% load step
Output Voltage THD < 1% linear load and < 2.5% nonlinear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 91.6%
Required Output Current Protection 144A
Bypass Internal Bypass (Automatic and Manual), Optional External Bypass
Input
Nominal Input Voltage 480V 3PH, 600V 3PH
Input Frequency 45 - 65 Hz, 60 Hz - programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8%
Input Connections
Hard Wire 4-wire (3PH + G)
Input voltage range for main operations 408 - 552 (480)V
Input voltage adjustable range for mains operation 408 - 552 (480V)V
Maximum Input Current 190A
Input Breaker Capacity 250 A
Maximum Short Circuit Withstand (Icw) 30.0 kA
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker

APC Smart-UPS VT SUVTP15KF4B4S
APC Smart-UPS VT SUVTP15KF4B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.0%Output Voltage Distortion Less than 5% at full loadOutput Frequency (sync t
APC MGE EPS 8000 UPS E8TUPS1100
APC MGE EPS 8000 UPS E8TUPS1100
Specifications:GeneralBypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G)Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 990 kW / 1.1 MVAMax Configurable Power 990 kW / 1.1 MVANominal Output Voltage 480V 3PHEfficiency at Full Load 92.0%Output Voltage
APC MGE EPS 8000 UPS E8TUPS750
APC MGE EPS 8000 UPS E8TUPS750
Specifications:GeneralBypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G)Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 1140AOutputOutput Power Capacity 675 kW / 750 kVAMax Configurable Power 675 kW / 750 kVANominal Output Voltage 480V 3PH, 600V 3PHEffi
APC Symmetra PX UPS SY64K160H
APC Symmetra PX UPS SY64K160H
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 64 kW / 64 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase
APC MGE Galaxy 3500 UPS G35T40KH4B4S
APC MGE Galaxy 3500 UPS G35T40KH4B4S
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync
APC Back-UPS BK500BLK
APC Back-UPS BK500BLK
Back-UPS specification:Output Power Capacity 300 Watts / 500 VAMax Configurable Power 300 Watts / 500 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50/60Hz +/- 3 HzTopology StandbyWaveform Type Stepped approximation to a sinewaveOutput Connections(3) NEMA 5-15R (Battery Backup) NEMA
APC Smart-UPS VT SUVTP10KH1B4S
APC Smart-UPS VT SUVTP10KH1B4S
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.2%Output Voltage Distortion Less than 5% at full loa
APC MGE Galaxy 3500 UPS G35T15K3I3B4S
APC MGE Galaxy 3500 UPS G35T15K3I3B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 230VEfficiency at Full Load 95.5%Output Voltage Distortion Less than 5%Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominalOther Output Voltages 220, 240Crest Factor Unlimite
APC MGE Galaxy 5000 UPS SUG5100S90UL
APC MGE Galaxy 5000 UPS SUG5100S90UL
Specifications:GeneralBypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G)OutputOutput Power Capacity 90 kW / 100 kVAMax Configurable Power 90 kW / 0 VANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 92.9%Output Voltage Distortion Less than 2%Output Frequency (sync to mains) 6
APC Back-UPS BX650CI-LM
APC Back-UPS BX650CI-LM
Back-UPS specification:Output Power Capacity 320 Watts / 575 VAMax Configurable Power 320 Watts / 575 VANominal Output Voltage 120VEfficiency at Full Load 70.0%Output Frequency (sync to mains) 50/60 Hz +/-1 HzTopology Line InteractiveWaveform Type Square waveOutput Connections(2) NEMA 5-15R (Surge P