Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / APC UPS Power Supply / APC MGE Galaxy 5000 UPS / APC MGE Galaxy 5000 UPS SUG5100S90UL

APC MGE Galaxy 5000 UPS SUG5100S90UL

APC MGE Galaxy 5000 UPS SUG5100S90UL
share

Specifications:
General
Bypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G)
Output
Output Power Capacity 90 kW / 100 kVA
Max Configurable Power 90 kW / 0 VA
Nominal Output Voltage 480V 3PH, 600V 3PH
Efficiency at Full Load 92.9%
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 60 Hz
Other Output Voltages 600
Crest Factor 3 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
Output Voltage Tolerance +/- 1% static and +/- 2 % at 100% load step
Output Voltage THD < 1% linear load and < 2.5% nonlinear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 91.6%
Required Output Current Protection 144A
Bypass Internal Bypass (Automatic and Manual), Optional External Bypass
Input
Nominal Input Voltage 480V 3PH, 600V 3PH
Input Frequency 45 - 65 Hz, 60 Hz - programmable +/- 0.5 / 1 / 2 / 4 / 6 / 8%
Input Connections
Hard Wire 4-wire (3PH + G)
Input voltage range for main operations 408 - 552 (480)V
Input voltage adjustable range for mains operation 408 - 552 (480V)V
Maximum Input Current 190A
Input Breaker Capacity 250 A
Maximum Short Circuit Withstand (Icw) 30.0 kA
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker

APC Back-UPS BE650G1-LM
APC Back-UPS BE650G1-LM
Back-UPS specification:Output Power Capacity 390 Watts / 650 VAMax Configurable Power 390 Watts / 0 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50 Hz, 60 HzTopology StandbyWaveform Type Stepped approximation to a sinewaveOutput Connections(4) NEMA 5-15R (Battery Backup) NEMA 5-15R(
APC Symmetra PX UPS SY10K100F
APC Symmetra PX UPS SY10K100F
Specifications:OutputOutput Power Capacity 10 kW / 10 kVAMax Configurable Power 100 kW / 100 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominalTopology Double Conversion OnlineWaveform Type Sine waveOutput
APC MGE EPS 7000 UPS E7TUPS400
APC MGE EPS 7000 UPS E7TUPS400
Specifications:GeneralMax Bypass Input Current 481AOutputOutput Power Capacity 360 kW / 400 kVAMax Configurable Power 360 kW / 400 kVANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 93.0%Output Voltage Distortion Less than 2%Output Frequency (sync to mains) 60 HzOther Output Voltage
APC Symmetra PX UPS SY20K40F
APC Symmetra PX UPS SY20K40F
Specifications:OutputOutput Power Capacity 20 kW / 20 kVAMax Configurable Power 40 kW / 40 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 5%Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominalCrest Factor UnlimitedTopology Double Conversion OnlineWaveform
APC MGE Galaxy 3500 UPS G35T10KF1B2S
APC MGE Galaxy 3500 UPS G35T10KF1B2S
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.2%Output Voltage Distortion Less than 5%Other Output
APC MGE Galaxy 5000 UPS G5TUPS60
APC MGE Galaxy 5000 UPS G5TUPS60
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 101AOutputOutput Power Capacity 54 kW / 60 kVAMax Configurable Power 54 kW / 60 kVANominal Output Voltage 400V 3PH, 480V 3PH, 600V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3
APC MGE Galaxy 3500 UPS G35T15KH2B4S
APC MGE Galaxy 3500 UPS G35T15KH2B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync
APC MGE Galaxy 5000 UPS G5TUPS130
APC MGE Galaxy 5000 UPS G5TUPS130
Specifications:OutputOutput Power Capacity 117 kW / 130 kVAMax Configurable Power 117 kW / 130 kVANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 94.5%Output Frequency (sync to mains) 60 HzOther Output Voltages 600Crest Factor 3 : 1Topology Double Conversion OnlineWaveform Type Sine
APC Smart-UPS SUA750RM2U
APC Smart-UPS SUA750RM2U
Smart-UPS Describtions:APC Smart-UPS,480 Watts /750 VA,Input 120V /Output 120V, Interface Port DB-9 RS-232, SmartSlot, USB, Rack Height 2 UIncludes: CD with software, Rack Mounting brackets, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable, User ManualStandard Lead Time: Usu
APC Symmetra PX UPS SY125K500DR-PD
APC Symmetra PX UPS SY125K500DR-PD
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 125 kW / 125 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out