Specifications:
General
Bypass Connection 5 wire (3PH + N + G)
Max Bypass Input Current 250A
Bypass Protection Device 250A
Output
Output Power Capacity 64 kW / 64 kVA
Max Configurable Power 160 kW / 160 kVA
Nominal Output Voltage 230V, 400V 3PH
Output Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Efficiency at Full Load 95.0%
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
Output Voltage THD < 2% for 0 to 100% linear load and < 6% for full non linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 95.0%
Required Output Current Protection 250A
Neutral Output Current 160A
Bypass Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH
Input Frequency 40 - 70 Hz
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 340 - 477V
Maximum Input Current 118A
Input Breaker Capacity 315 A
Maximum Short Circuit Withstand (Icw) 30.0 kA
Input Total Harmonic Distortion Less than 5% for full load

APC MGE Galaxy 4000 UPS G4TUPS40
APC MGE Galaxy 4000 UPS G4TUPS40
Specifications: General Bypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G) Bypass Voltage Tolerance +/- 15% Max Bypass Input Current 111A Output Output Power Capacity 32 kW / 40 kVA Max Configurable Power 32 kW / 40 kVA Nominal Output Voltage 208V 3PH Efficiency at Full Load 89.0%
APC Symmetra PX UPS SY100K250DR-PD
APC Symmetra PX UPS SY100K250DR-PD
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 100 kW / 100 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Symmetra PX UPS SY20K40F
APC Symmetra PX UPS SY20K40F
Specifications:OutputOutput Power Capacity 20 kW / 20 kVAMax Configurable Power 40 kW / 40 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 5%Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominalCrest Factor UnlimitedTopology Double Conversion OnlineWaveform
APC MGE EPS 8000 UPS E8TUPS800
APC MGE EPS 8000 UPS E8TUPS800
Specifications:GeneralBypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G)Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 1215AOutputOutput Power Capacity 720 kW / 800 kVAMax Configurable Power 720 kW / 800 kVANominal Output Voltage 480V 3PH, 600V 3PHOutp
APC Smart-UPS VT SUVTRT20KF5B5S
APC Smart-UPS VT SUVTRT20KF5B5S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.0%Output Voltage Distortion Less than 5% at full lo
APC Smart-UPS VT SUVTP30KF4B4S
APC Smart-UPS VT SUVTP30KF4B4S
Specifications:OutputOutput Power Capacity 24 kW / 30 kVAMax Configurable Power 24 kW / 30 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.3%Output Voltage Distortion Less than 5% at full loadOutput Frequency (sync t
APC MGE Galaxy 3500 UPS G35T15KHS
APC MGE Galaxy 3500 UPS G35T15KHS
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync
APC Symmetra PX UPS SY125K250DL-PD
APC Symmetra PX UPS SY125K250DL-PD
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 125 kW / 125 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Symmetra PX UPS SY96K96H-NB
APC Symmetra PX UPS SY96K96H-NB
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 96 kW / 96 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase
APC MGE Galaxy 5000 UPS SUG580A90UL
APC MGE Galaxy 5000 UPS SUG580A90UL
Specifications:OutputOutput Power Capacity 72 kW / 80 kVAMax Configurable Power 72 kW / 0 VANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 92.8%Output Voltage Distortion Less than 2%Output Frequency (sync to mains) 60 HzCrest Factor 3 : 1Topology Double Conversion OnlineOutput Conn