Descriptions:the Powerware 9125 UPS delivers the ultimate in protection,
truly isolating your equipment from all nine of the common
power anomalies lurking in public utility power. Available
as either a rackmount or stand-alone unit, the compact
and elegant 9125 supplies continuous, conditioned power
to all connected equipment,delivering large-scale power
protection in a sleek package small enough to fit beneath
your desk.

Powerware 9170 Online UPS PW9S9K-PD
Powerware 9170 Online UPS PW9S9K-PD
Specifications:Technical InformationPlug/Connector Type HardwiredReceptacles 2 x NEMA L14-30R2 x NEMA L6-30R12 x NEMA 5-20RPower DescriptionLoad Capacity 9 kVA/6.30 kWInput Voltage 110 V AC/220 V ACInput Voltage Range 120 V AC/208 V AC/240 V ACOutput Voltage 120 V AC/208 V AC/240 V ACFrequency 50 Hz
Powerware 9315-160 UPS Model 160 160kVA/128kW
Powerware 9315-160 UPS Model 160 160kVA/128kW
Specifications:InputVoltage range: (See chart on other side)Frequency range: (60 Hz) 57-63 Hz; (50 Hz) 47-53HzPower factor: 0.95 typical at full load with inputfilter. Input current distortion lessthan 7% with input filtOutputVoltage regulation: Better than ±1%Transient response: Less than 5% for 1
Powerware Plus18 UPS Model 18
Powerware Plus18 UPS Model 18
Specifications: Input Frequency Range 45-65 Hz Power Factor 0.95 Typical at full load Output Voltage Regulation Better than +/- 3% Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load)Transient Response Less than 5% for 100% load, step full recovery within 1/4 cycl
Powerware 9305 UPS PW9305-15I-N
Powerware 9305 UPS PW9305-15I-N
Specifications:Rating 15 kVACapacity (VA/Watts) 15 / 10.5Dimensions WxDxH (mm) 400x750x700 Weight (kg) 220Input connection Hardwired Output connection HardwiredTypical runtime (Full load) 30 min (Half load) 18 min
Powerware 5119 Rackmount UPS PW5119 1599iRM
Powerware 5119 Rackmount UPS PW5119 1599iRM
Specifications:Electrical InputVoltage 120 and 230 VAC NominalOn Line Voltage Range -30%, +20% for nominal voltages; user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)Nominal Input Frequency 50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)Frequency Tolerance No
Powerware 9 Prestige UPS Model 1000VA/700W
Powerware 9 Prestige UPS Model 1000VA/700W
Specifications: Rating: 650-6000 VA Input Voltage: 120 Vac; 200–240 Vac Output Voltage: 120 Vac; 120/208 120/240 Vac Frequency: 50/60 Hz Configuration: Modular; rack-mount and cabinet
Powerware 5119 UPS PW5119 3000
Powerware 5119 UPS PW5119 3000
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Eaton Powerware 5110 UPS 51100700A
Eaton Powerware 5110 UPS 51100700A
Specifications:Capacity 700VA/420WDimensions (mm) HxWxD 270x87x260Unit Weight (kg) 5 6 8 12 12.5Input Connection 1.8 metre line cord IEC to Australian 10Amp PlugOutput Connection 6 Australian 10Amp Outlets (3 Battery Backup & Surge Protection,3 Surge Protection only)OperationInput Voltage Range (on-
Powerware 5125 RM UPS 51251000IRMBLK
Powerware 5125 RM UPS 51251000IRMBLK
Technical SpecificationsRating 1000VA Capacity (VA/watts) 1000/900Dimensions WxDxH (mm) 432x494x89 Weight (kg) 27 Input connection IEC320/10AOutput connection 6 x IEC320/10A Typical Runtime (full load) pf 0.9 (half load)7 min 19 min
Powerware BPIII 300 Industrial UPS 225-300 kVA
Powerware BPIII 300 Industrial UPS 225-300 kVA
Specifications:Input SpecificationsFrequency range: (60 Hz) 57-63 HzSurge protection: Meets ANSI C62.41Category A & B: EN 50091-2, and EN 50082-2Power factor: 0.95 typical at full load with input filterInput currentdistortion: less than 7% with input filterOutput SpecificationsVoltage THD: Less than