Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / Riello UPS Power Supply / Riello Sentinel Power Green UPS SPH 8

Riello Sentinel Power Green UPS SPH 8

Riello Sentinel Power Green UPS SPH 8
share

Specifications:
INPUT
Voltage 220-230-240 Vac
Frequency 50/60 Hz +/- 10 Hz
BY PASS
Voltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)
Frequency tolerance Selected frequency ±10%
OUTPUT and INVERTER OUTPUT
Rated power 8000 VA
Active power 7200 W
Waveform Sinusoidal
OVERLOAD TIMES
100% < Load < 110% 5 min
100% < Load < 120% 1 min
125% = Load < 150% 10 sec
Load = 150% 0,1 sec
BATTERIES
Type VRLA AGM maintenance-free lead based
Typical recharge time 6-8 hours

Riello Master HP UL UPS MHT UL 100
Riello Master HP UL UPS MHT UL 100
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)100/90 %Input voltage distoration (THDi) <3 Outpu
Riello Master MPS UPS MPT 20
Riello Master MPS UPS MPT 20
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated fre
Riello Master HE UPS MHE 500
Riello Master HE UPS MHE 500
Specifications: INPUT Rated power 500000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 702 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Master HE UPS MHE 100
Riello Master HE UPS MHE 100
Specifications:INPUTRated power 100000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 141 ACurrent distorsion
Riello Master MPS UPS MPT 160
Riello Master MPS UPS MPT 160
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph
Riello Master HE UPS MHE 250
Riello Master HE UPS MHE 250
Specifications: INPUT Rated power 250000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 352 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Multi Sentry UPS MST 40
Riello Multi Sentry UPS MST 40
Specifications:INPUTRated power 40000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Power Green UPS SPH 8
Riello Sentinel Power Green UPS SPH 8
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 8000 VAActive power 7200 WWaveform SinusoidalOVERLOAD TIMES
Riello Master HP UPS MHT 200
Riello Master HP UPS MHT 200
SpecificationsINPUTRated power 200000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 281 ACurrent distorsion
Riello Master HP UPS MHT 400
Riello Master HP UPS MHT 400
SpecificationsINPUTRated power 400000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 564 ACurrent distorsion