SAM Solar Inverters without Transformer SUNNY BOY 9000TL-US
share

With peak efficiencies of 98.3%, the transformerless Sunny Boy TL-US provide their owners with high yields. The power classes, finely tiered from 6 kW to 11kW, are ideal for designing mid-size solar power plants with precision. Its reduces weight, together with its security features, make our Sunny Boy the ideal inverter.
Innovative
First transformerless SMA inverter to be certified in accordance with UL 1741 with safety standards from IEC 62109
First inverter with arc-fault circuit interrupter listed according to UL1699B
Economical
Maximum efficiency of 98.3%
The best MPP tracking efficiency with OptiTrac MPP tracking
Transformerless, with H5 topology
OptiCool active temperature management
Reliable
Integrated DC switch-disconnector
SMA Power Balancer for threephase grid connection
With arc-fault circuit interrupter (AFCI)
Input (DC)
Max. recommended PV power (@ module STC) 11250 W12500 W
Max. DC power (@ cos Ï† = 1) 9400 W10400 W
Max. input voltage 600 V
MPP voltage range / rated input voltage 300 V â€“ 480 V / 345 V345 V â€“ 480 V / 379 V
Min. input voltage / initial input voltage 300 V / 360 V345 V / 360 V
Max. input current 31.4 A30.2 A
Max. input current per string 31.4 A30.2 A
Number of independent MPP inputs 1
Strings per MPP input @ Combiner Box 6
-Output (AC)
Rated power / max. apparent AC power 9000 W / 9000 VA
Nominal AC voltage / nominal AC voltage range 208 V / 183 V â€“ 229 V240 V / 211 V â€“ 264 V
AC power frequency / range 60 Hz / 59.3 Hz ... 60.5 Hz
Max. output current 43.3 A41.7 A
Power factor at rated power 1
Feed-in phases / connection phases 1 / 2
-Efficiency
CEC efficiency / max. efficiency 98 % / 98.3 %
-Protective devices
DC reverse polarity protection yes
AC short-circuit current capability yes
Galvanic isolation —
All-pole-sensitive residual-current monitoring unit yes
Arc-fault circuit interrupter (according to UL 1699B) yes
Protection class (according to IEC 62103) I
Overvoltage category (according to IEC 60664-1) IV
-General data
Dimensions (W / H / D) 470 / 615 / 240 mm(18.4 / 24.1 / 9.5 inch)
Dimensions of DC Disconnect (W / H / D) 187 / 297 / 190 mm(7.28 / 11.7 / 7.5 inch)
Weight 35 kg / 78 lb
Weight of DC Disconnect 3.5 kg / 8 lb
Operating temperature range -40 °C ... +60 °C /-40 °F ... +140 °F
Noise emission (typical) 46 dB(A)
Self-consumption (night) 0.15 W
Topology Transformerless H5
Cooling concept OptiCool
Degree of protection NEMA 3R
Degree of protection of connection area NEMA 3R
Max. permissible value for relative humidity (non-condensing) 100 %
-Features
DC connection Screw terminal
AC connection Screw terminal
Display Text line
Interface: RS485 /Bluetooth opt. / opt.
Warranty: 10 / 15 / 20 years yes / opt. / opt.
Certificates and approvals (more available on request) UL1741, UL1998, IEEE1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1, UL 1699B

SMA Solar Inverters with Transformer SUNNY BOY 3000HF
SMA Solar Inverters with Transformer SUNNY BOY 3000HF
The Sunny Boy HF offers a nearly unlimited range of options for the planning phase. A wide input voltage range of 175-700 volts means that most configurations can&nb
SAM Solar Inverters without Transformer SUNNY BOY 1600TL
SAM Solar Inverters without Transformer SUNNY BOY 1600TL
Combining a broad input voltage range and a broad input current range, the transformerless Sunny Boy can be connected to nearly all standard crystalline PV modules. As&nb
SAM Solar Inverters without Transformer SUNNY TRIPOWER 12000TL
SAM Solar Inverters without Transformer SUNNY TRIPOWER 12000TL
Optiflex is the first of our new features.Its outstanding flexibility opens up endless possibilities.How? Through an asymmetrically dimensioned multistring input combined with a broad&n
SMA Solar Inverters with Transformer SUNNY BOY 3800
SMA Solar Inverters with Transformer SUNNY BOY 3800
It is robust, easy-to-handle, and, thanks to its galvanic isolation, can be used in all kinds of AC grids: the Sunny Boy 3300 / 3800. Due to its suitability&nbs
SAM Solar Inverters without Transformer SUNNY TRIPOWER 17000TL
SAM Solar Inverters without Transformer SUNNY TRIPOWER 17000TL
Optiflex is the first of our new features.Its outstanding flexibility opens up endless possibilities.How? Through an asymmetrically dimensioned multistring input combined with a broad&n
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 10000TLRP
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 10000TLRP
Sunny Mini Central inverters with Reactive Power Control are the ideal solution when utility companies demand reactive power supply. They can be used to realize plant des
SMA Solar Inverters with Transformer SUNNY BOY 2500
SMA Solar Inverters with Transformer SUNNY BOY 2500
Universally applicable: the Sunny Boy inverters 1200, 1700, 2500 and 3000 are used in the most diverse AC grids thanks to their galvanic isolation. In addition, the 
SAM Solar Inverters without Transformer SUNNY BOY 2100TL
SAM Solar Inverters without Transformer SUNNY BOY 2100TL
Combining a broad input voltage range and a broad input current range, the transformerless Sunny Boy can be connected to nearly all standard crystalline PV modules. As&nb
SMA Solar Inverters with Transformer SUNNY BOY 2500HF-US
SMA Solar Inverters with Transformer SUNNY BOY 2500HF-US
This is the new generation of inverters designed for the countries with UL listing â€“ packed full of the latest SMA technology, these devices provide the highest&nb
SAM Solar Inverters without Transformer SUNNY BOY 3000TL RPC
SAM Solar Inverters without Transformer SUNNY BOY 3000TL RPC
Electrifying detail: Thanks to the higher, 750 volt maximum DC input voltage, often times one less module string is needed because more modules can be switched on in