Omron Power Supply S8VM Series S8VM-10012D

Omron Power Supply S8VM Series S8VM-10012D
share

Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 100 W , Output 12 V 8.5 A
Power rating 100 W
Efficiency 81% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 1.4 A Max. ï¼ˆAt 100 VAC input)0.7 A Max. ï¼ˆAt 200 VAC input)
Power factor 0.98 Min. (At 100 VAC input)0.94 Min. (At 200 VAC input)
Harmonic Current EN61000-3-2
Leakage current 0.4 mA Max. (At 100 VAC input)0.75 mA Max. (At 200 VAC input)
Inrush current 17.5 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))35 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 12 VDC
Output voltage variable range -20 to +20% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +20% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 1.5%(p-p) Max.
Static input variation influence 0.4% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.02 %/CEL Max. (At rated input/output voltage)
Rated output current 8.5 A
Start up time 800 ms Max. ï¼ˆAt rated input/output voltage)
Hold time 20 ms TYP.
Overload protection 105% to 160% of the rated output currentInverted L voltage drop, Automatic reset
Overvoltage protection Operated at 140% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm indication No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function Yes
Applicable standard (UL) Standard No.: UL508 (Listing), UL60950-1, UL1604 (Listing, Class I / Division 2)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.14, No.213 (Class I / Division 2), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class B
Applicable standard(SEMI) F47-0200 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 30 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE/FG terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE/FG terminals: 500 VAC for 1 min (Detection current: 100 mA)
Insulation resistance Between all outputs and all inputs/ PE/FG terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Open-frame type
Mounting type DIN Rail mounting type
Attachment Instruction manual

Omron Power Supply S8EX Series S8EX-BP15024L
Omron Power Supply S8EX Series S8EX-BP15024L
With chassis , Input 100 to 240 VAC , 150W , Output 24V 6.3APower rating 150 WEfficiency 84% Min. ï¼ˆAt 100 VAC input)87% Min. ï¼ˆAt 200 VAC input)Rated 
Omron S8JX Switch Mode Power S8JX-G05048
Omron S8JX Switch Mode Power S8JX-G05048
Covered type , Input 100 to 240 VAC , 50 W , Output 48 V 1.1 A , Front-mounting typePower rating 50 WEfficiency 82% Min.Rated input voltage 100 to 240 VACAllowable-i
Omron S8JX Switch Mode Power S8JX-G03515CD
Omron S8JX Switch Mode Power S8JX-G03515CD
Covered type , Input 100 to 240 VAC , 35 W , Output 15 V 2.4 A , DIN Rail mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated inp
Omron Power Supply S8VS Series S8VS-18024BE
Omron Power Supply S8VS Series S8VS-18024BE
Total Run Time Monitor , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 APower rating 180 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)87% TYP. ï¼ˆAt 200 
Omron Power Supply S8VS Series S8VS-12024BP
Omron Power Supply S8VS Series S8VS-12024BP
Standard Model , Input 100 to 240 VAC , 15 W , Output 12 V 1.2 APower rating 15 WEfficiency 79% TYP. ï¼ˆAt 100 VAC input)78% TYP. ï¼ˆAt 200 VAC input)Rate
Omron Power Supply S8VS Series S8VS-24024BE-F
Omron Power Supply S8VS Series S8VS-24024BE-F
TotalPower rating 240 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)88% TYP. ï¼ˆAt 200 VAC input)Rated input voltage 100 to 240 VACAllowable-input voltage variable range 85 to 264 VAC8
Omron Power Supply S8JX Switch Mode Power S8JX-P15012D
Omron Power Supply S8JX Switch Mode Power S8JX-P15012D
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 12V 13A , DIN Rail mounting typePower rating 150 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-in
Omron Power Supply S8VM Series S8VM-01524A
Omron Power Supply S8VM Series S8VM-01524A
Undervoltage Alarm Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 15 W , Output 24 V 0.65 APower rating 15 WEfficiency 80% Min.Rated input&
Omron Power Supply S8VM Series S8VM-03005D
Omron Power Supply S8VM Series S8VM-03005D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 30 W , Output 5 V 6 APower rating 30 WEfficiency 75% Min.Rated in
Omron S8JX Switch Mode Power S8JX-G05005D
Omron S8JX Switch Mode Power S8JX-G05005D
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 5V 10A , DIN Rail mounting typePower rating 50 WEfficiency 76% Min.Rated input voltage 100 to 240 VACAllowable-input