Specifications:
INPUT
Rated power 800 VA
Voltage 220-240 Vac
Voltage tolerance 230 Vac (+ 20 / - 25%)
Frequency 50/60 Hz auto sensing
OUTPUT and INVERTER OUTPUT
Rated power 800 VA
Active power 480 W
Number phases 1
Wave form on battery Pseudo sinewave
Frequency on battery operation 50 or 60 Hz (± 1%)

Riello Vision Dual UPS VSD 1500
Riello Vision Dual UPS VSD 1500
Specifications: INPUT Rated power 1500 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 1500 VA Active power 1350 W Number phases 1 Crest factor (Ipea
Riello Multi Sentry UPS MSM 15
Riello Multi Sentry UPS MSM 15
Specifications:INPUTRated power 15000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Master Industrial UPS MIM 40
Riello Master Industrial UPS MIM 40
Specifications: INPUT Rated power 40000 VA Voltage 400 Vac three-phase Vac Voltage tolerance ± 20% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0.93 Current distorsion <5% Soft start 0-100% in 120" configurable BY PASS Rated voltage 400 Vac three-phase s
Riello Dialog Vision UPS DVR 500
Riello Dialog Vision UPS DVR 500
Specifications: INPUT Rated power 500 VA Voltage 230 Vac Frequency 50/60 Hz with autorange Frequency tolerance ± 10Hz OUTPUT and INVERTER OUTPUT Rated power 500 VA Active power 335 W Number phases 1 Waveform Sinewave Frequency 50 or 60 Hz with autorange BATTERIES Type Maintenance-free
Riello Sentinel Power UPS SPT 10000
Riello Sentinel Power UPS SPT 10000
Specifications:INPUTRated power 10000 VAVoltage 220-230-240 Vac single-phase or 380-400-415 Vac three-phase with neutral VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Freq
Riello Multi Sentry UPS MCM 20
Riello Multi Sentry UPS MCM 20
Specifications:INPUTRated power 20000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Master HE UPS MHE 600
Riello Master HE UPS MHE 600
Specifications: INPUT Rated power 600000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 842 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Sentinel Pro UPS SEP 1500
Riello Sentinel Pro UPS SEP 1500
Specifications:INPUTRated power 1500 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Master HP UL UPS MHT UL 100
Riello Master HP UL UPS MHT UL 100
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)100/90 %Input voltage distoration (THDi) <3 Outpu
Riello Multi Sentry UPS MST 40
Riello Multi Sentry UPS MST 40
Specifications:INPUTRated power 40000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25